CONFIGURATION
–
Movements
Opens the movement values configuration screen.
Attention: these values should only be modified with real knowledge of the facts. Incorrect values can cause major
malfunctions of your printer, and even damage it irreparably
.
Here you will find the maximum speed settings for each axis, as well as the acceleration and step settings per
millimeter.
CONFIGURATION
–
Motors
Motor Direction and Enable Signal Parameter Page:
(*) The logo displayed on the screenshots may vary, but the content remains the same on all models.
-
“Axis” direction (E1 being the Extruder):
Defines the direction of movement of an axis. If it goes in the
wrong direction (following a change of motor reference for example), invert the corresponding value
here.
-
“Axis” activation (E being Extruder):
Defines the motor driver activation signal. This can be useful if