CONFIGURATION - Temperatures
Temperature management settings page:
(*) The logo displayed on the screenshots may vary, but the content remains the same on all models.
-
Nozzle temp compensation:
Sets the number of degrees to automatically add to print program
temperatures to compensate for other nozzle types without changing print profiles, for example with a
hardened steel nozzle which requires approximately 15-20°C warmer than a copper/nickel nozzle for the
same result.
-
Temp. Filament loading
: Defines in °C the automatic loading temperature of the filament. The default
value is 220°C.
-
Wire loading speed
: Defines in mm/min (millimeter/minute) the automatic filament loading speed. The
default is 130mm per minute.
-
Hood fan speed
: Sets the speed in percentage of the hood fan if installed. If the “Fan. Auto cover” is
activated in the “Configuration –
Detections” menu, the setting chosen by the machine will be displayed
here, any modification will have no effect in this case.
-
Extruder heating standby time
: Sets the delay before the extruder puts the heater on standby when
waiting for the user.
-
Minimum extrusion temperature
: Sets the minimum temperature where extrusion will be possible,
below this, t
he extruder will not activate the motor to avoid “cold extrusions”.
-
Head PID
: display of the "PID" values of the head calculated by the "Heating calibration -> Head" function.
-
PID reads
: display of the “PID” values
of the heated bed
calculated by the “Heater calibration
-
> Bed”
function.