61
DC voltage
Range
Resolution
Accuracy*
400.0 mV
0.1 mV
±(0.8% + 8)
4.000 V
0.001 V
±(1.2% + 5)
40.00 V
0.01 V
400.0 V
0.1 V
600 V
1 V
±(1.5% + 5)
600 V overload protection; Impedance: ≥10 MΩ
Permitted display with short-circuited measuring input: ≤5 Counts
*Accuracy: 5 - 100% of the measuring range
Resistance
Range
Resolution
Accuracy*
400.0 Ω
0.1 Ω
±(1.2% + 5)
4.000 kΩ
0.001 KΩ
±(1.0% + 5)
40.00 KΩ
0.01 KΩ
±(1.2% + 5)
400.0 KΩ
0.1 KΩ
4.000 MΩ
0.001 MΩ
40.00 MΩ
0.01 MΩ
±(2.0% + 5)
Overload protection 600 V; Measuring voltage: approx. 0.5 V
*Accuracy: 5 - 100% of the measuring range; <400 Ω with zero adjustment (REL function)
Capacitance
Range
Resolution
Accuracy*
400.0 nF
0.1 nF
±(3.0% + 5)
4.000 µF
0.001 µF
40.00 µF
0.01 µF
100.0 µF
0.1 µF
±(5.0% + 10)
600 V overload protection
Permitted display with open measuring input: ≤5 Counts
*Accuracy: 5 - 100% of the measuring range; ≤1 µF with zero adjustment (REL function)