2.1 BEFORE SWITCHING ON
Before switching the appliance on, please familiarise yourself with:
- how to isolate the appliance from the gas, water, and elec-
tricity supplies;
- how to check and top-up – if necessary – the system water
pressure;
- the time clock or programmer (if fitted);
- any external thermostats and their functions;
- the appliance controls.
2.2 APPLIANCE CONTROLS (see fig. 1)
The appliance controls are situated on the lower front of the
appliance. The appliance controls include:
- pressure gauge;
- appliance mode selector;
- temperature selector;
- burner ON mode (green);
- fault indicator (red);
- servicing mode indicator (red+green)
- optional integral time clock/programmer (if fitted).
NOTE
The appliance frost protection is active in all the boiler modes.
The
temperature selectors
can be used to vary the temperature
of the water that circulates around your radiators and the water
that flows from your hot water taps. The temperature range is
adjustable between 40
o
C and 80
o
C for the central heating, and
between 37
o
C and 60
o
C for the hot water.
When the
status indicator (Green) is lit
it indicates that the
flame is present and the burner is ON.
When the
fault indicator (Red) is lit
it indicates that the
appliance has identified a possible fault and performed a safety
lockout.
The
integral time clock (when fitted)
can be used to switch the
heating on and off at pre-determined intervals.
2.3 LIGHTING THE BOILER
Ensure the gas and electrical supply to the boiler are turned on.
Turn the mode selector switch to the
ON
position. When there
is a request for heating or hot water via the time clock or
programmer, the boiler will begin an ignition sequence. When
the appliance reaches the CH set temperature, the burner will
go off for a minimum period of approximately 3 minutes.
When the programmer/time clock or external thermostats
heating request has been satisfied, the appliance will switch
off automatically.
2.4 ADJUSTING THE HEATING TEMPERATURE
Rotate the temperature selector – clockwise to increase,
counter-clockwise to decrease – to the desired temperature
setting. The temperature can be set from a minimum of 40°C
to a maximum of 80°C (if standard CH mode is selected).
2.5 ADJUSTING THE HOT WATER TEMPERATURE
Rotate the temperature selector – clockwise to increase,
counter-clockwise to decrease – to the desired temperature
setting. The temperature can be set from a minimum of 37°C
to a maximum of 60°C. If the temperature at the outlet is still not
sufficiently hot enough, it may be necessary to reduce the flow
of water at the hot water outlet (tap).
NOTE
If the appliance fails to ignite during the ignition sequence, it will
enter a lockout condition. Should this occur, please allow a
period of at least two minutes before re-setting the appliance.
2.6 EXPLANATION OF FEATURES
Although the Vokèra Compact SE has been designed for
simplicity of use, it utilises the latest in boiler technology,
enabling a host of functions to be carried out simultaneously.
2.7 AUTOMATIC TEMPERATURE CONTROL
The automatic temperature control function (SARA), permits
the boiler (when the heating temperature selector is set in
position AUTO) to automatically adjust (raise) the heating.
The activation and the disable of the function is visualized by
blinking the green led.
2. GETTING STARTED
3.1 HOW TO TOP-UP THE SYSTEM PRESSURE
(fig. 1-2)
The system pressure must be checked periodically to ensure
the correct operation of the boiler. The needle on the gauge
should be reading between 1 and 1.5 BAR when the boiler is
in an off position and has cooled to room temperature. If the
pressure requires ‘topping-up’ use the following instructions
as a guide.
- Locate the filling valve connections (usually beneath the
boiler, see fig. 2).
- Attach the filling loop to both connections.
- Open the filling valve slowly until you hear water entering the
system.
- Close the filling valve when the pressure gauge (on the
boiler) reads between 1 and 1.5 BAR (see fig. 1).
- Remove the filling loop from the connections.
3.2 HOW TO RESET THE APPLIANCE
When the red fault LED is illuminated, the appliance will require
to be reset manually. Before resetting the boiler, check what
action is required to be taken, using the information on the
fault code table below. Allow a period of two minutes to
elapse before rotate the mode selector knob across the
position (see fig. 1).
IMPORTANT
If the appliance requires to be reset frequently, it may be
indicative of a fault, please contact your installer or Vokèra
Customer Services for further advice.
3. HOW TO...
Fig. 2
control
valve
temporary
connection
control
valve
supply pipe
double
check valve
flow/return
pipe
3.3 HOW TO SHUT DOWN THE SYSTEM FOR
SHORT PERIODS
The system and boiler can be shut down for short periods by
simply turning the time clock to the off position. It is also
advisable to turn off the main water supply to the house.
3.4 HOW TO SHUT DOWN THE SYSTEM FOR
LONG PERIODS
If the house is to be left unoccupied for any length of time –
especially during the winter – the system should be thoroughly
drained of all water. The gas, water, and electricity supply to the
house should also be turned off. For more detailed advice
contact your installer.
3.5 HOW TO CARE FOR THE APPLIANCE
To clean the outer casing use only a clean damp cloth. Do
n o t u s e a n y
s c o u r e r s o r
a b r a s i v e
cleaners.