GAS BOILER SYSTEM COMMISSIONING CHECKLIST
CONTROLS
Tick the appropriate boxes
Time and Temperat
u
re Control to Heating
Room Thermostat and
Programma
b
le
Load/
W
eather
Optim
u
m Start
Programmer/Timer
Room
Thermostat
Compensation
Control
Time and Temperat
u
re Control to Hot
W
ater
Cylinder Thermostat and Programmer/Timer
Com
b
ination Boiler
Heating Zone
V
al
v
es
Fitted
N
ot Re
qu
ired
Hot
W
ater Zone
V
al
v
es
Fitted
N
ot Re
qu
ired
Thermostatic Radiator
V
al
v
es
Fitted
N
ot Re
qu
ired
A
u
tomatic Bypass to System
Fitted
N
ot Re
qu
ired
Boiler Interlock
Pro
v
ided
ALL SYSTEMS
The system has
b
een fl
u
shed and cleaned in accordance
w
ith BS7593 and
b
oiler man
u
fact
u
rer’s instr
u
ctions Yes
W
hat system cleaner
w
as
u
sed?
W
hat inhi
b
itor
w
as
u
sed?
Q
u
antity
litres
CENTRAL HEATING MODE
Measure and Record:
Gas Rate
m
3
/hr OR
ft
3
/hr
B
u
rner Operating Press
u
re (if applica
b
le)
m
b
ar OR
Gas
Inlet
Press
u
re
m
b
ar
Central Heating Flo
w
Temperat
u
re
°C
Central Heating Ret
u
rn Temperat
u
re
°C
COMBINATION BOILERS ONLY
Is the installation in a hard
w
ater area (a
b
o
v
e 200ppm)?
Yes
N
o
If yes, has a
w
ater scale red
u
cer
b
een fitted?
Yes
N
o
W
hat type of scale red
u
cer has
b
een fitted?
DOMESTIC HOT WATER MODE Measure and Record:
Gas Rate
m
3
/hr OR
ft
3
/hr
B
u
rner Operating Press
u
re (at maxim
u
m rate)
m
b
ar
OR
Gas Inlet Press
u
re (at maxim
u
m rate)
m
b
ar
Cold
W
ater Inlet Temperat
u
re
°C
Hot
w
ater has
b
een checked at all o
u
tlets
Yes
Temperat
u
re
°C
W
ater Flo
w
Rate
l/min
CONDENSING BOILERS ONLY
The condensate drain has
b
een installed in accordance
w
ith the man
u
fact
u
rer’s instr
u
ctions and/or BS5546/BS679
8
Yes
ALL INSTALLATIONS
If re
qu
ired
b
y the man
u
fact
u
rer, record the follo
w
ing
CO
2
%
OR CO
ppm OR CO/CO
2
Ratio
The heating and hot
w
ater system complies
w
ith the appropriate B
u
ilding Reg
u
lations
Yes
The
b
oiler and associated prod
u
cts ha
v
e
b
een installed and commissioned in accordance
w
ith the man
u
fact
u
rer’s instr
u
ctions
Yes
The operation of the
b
oiler and system controls ha
v
e
b
een demonstrated to and
u
nderstood
b
y the c
u
stomer
Yes
The man
u
fact
u
rer’s literat
u
re, incl
u
ding Benchmark Checklist and Ser
v
ice Record, has
b
een explained and left
w
ith the c
u
stomer
Yes
*
All installations in England and
W
ales m
u
st
b
e notified to Local A
u
thority B
u
ilding Control (LABC) either directly or thro
u
gh a Competent Persons Scheme.
A B
u
ilding Reg
u
lations Compliance Certificate
w
ill then
b
e iss
u
ed to the c
u
stomer.
©Heating and Hot
w
ater Ind
u
stry Co
u
ncil (HHIC)
www
.centralheating.co.
u
k
Commi ssioning Engineer’s Signat
u
re
C
u
stomer’s Signat
u
re
(To confirm satisfactory demonstration and receipt of man
u
fact
u
rer’s literat
u
re)
This Commissioning Checklist is to
b
e completed in f
u
ll
b
y the competent person
w
ho commissioned the
b
oiler as a means of demonstrating
compliance
w
ith the appropriate B
u
ilding Reg
u
lations and then handed to the c
u
stomer to keep for f
u
t
u
re reference.
Fail
u
re to install and commission this e
qu
ipment to the man
u
fact
u
rer’s instr
u
ctions may in
v
alidate the
w
arranty
bu
t does not affect stat
u
tory rights.
C
u
stomer
N
ame
Telephone
Nu
m
b
er
Address
Boiler Make and Model
Boiler Serial
Nu
m
b
er
Commissioned
b
y (print
name)
CORGI
ID
Nu
m
b
er
Company
N
ame
Telephone
Nu
m
b
er
Company Address
Commissioning Date
To be completed by the customer on receipt of a Buildin
g
Re
g
ulations Compliance Certificate
*
:
B
u
ilding Reg
u
lations
N
otification
Nu
m
b
er (if applica
b
le)