3
Dimensions
26 11/32 [669.0 mm]
13 5/32 [334.5 mm]
27 1/32 [686.6 mm]
21 13/16 [554.0 mm]
22 1/4 [565.0 mm]
15 1/2 [394.0 mm]
4 11/16 [118.8 mm]
44 7/32 [1123.0 mm]
6.00 INSIDE
22. DO NOT ROUTE THE blower power SUPPLY CORD
NEAR OR ACROSS HOT SURFACES!
23.
Canada Installations requires that this fireplace
must be installed with a continuous chimney liner
of 6 inch diameter extending from the fireplace
insert to the top of the chimney. The chimney liner
must conform to the Class 3 requirements of CAN/
ULC-S635, Standard for Lining Systems for Existing
Masonry or Factory-Built Chimneys and Vents, or
CAN/ULC-S640, Standard for Lining Systems for
New Masonry Chimneys.
24. Permanently seal any opening between the
masonry of the fireplace and the facing masonry.
25. Fireplace insert surround panels may be removed
to inspect fireplace insert and fireplace.
26.
U.S. Stove Company requires installing smoke
detectors in the same room as the heater if not
already installed. Smoke expelled from the unit by
either paint curing, opening the fuel loading door,
or a negative pressure inside the home could
trigger the smoke detectors.
27. For further information on using your heater safely,
obtain a copy of the National Fire Protection
Association (NFPA) publication “Using Coal and
Wood Stoves Safely” NFPA No. HS-10-1978. The
address of the NFPA is 1 Battery March Park,
Quincy, MA. 02269.