Supplied By www.heating spares.co Tel. 0161 620 6677
25
Linea Plus AG
8
.12
Ignition PCB
8.12.1
Gain general access as 8.4.
8.12.2
Remove PCB cover.
8.12.3
Disconnect wires from ignition PCB.
8.12.4
Remove ignition PCB.
8.12.5
Replace in the reverse order ensuring wires
are replaced correctly.
8.13
Gas Control Valve (complete)
Part No. 2471 fig. 31.
8.13.1
Turn off gas service tap.
8.13.2
Remove Ignition control box as 8.12.
8.13.3
Pull off silicone tube from gas valve regulator.
8.13.4
Disconnect earth leads from gas valve.
8.13.5
Disconnect wires from modulator coil.
8.13.6
Unscrew gas service tap union & release from
its seating.
8.13.7
Remove 2 screws securing gas valve bracket
to the base frame.
8.13.8
Undo union above the gas control valve &
withdraw gas valve.
8.13.9
Transfer gas connecting pipes to the new
valve using new gasket.
8.13.10
Reassemble in reverse order.
8.13.11
Test all joints for gas soundness.
8.13.12
Check burner pressures. As detailed in 6.6.
Pipe Securing Clip
Silicone Compensation
Tube Point
Modulator
Coil
Fig. 31
Fig. 32
Pump
Securing
Bracket
Protective
cover