Linea Plus AG
IMPORTANT
DO NOT USE SMALLER TERMINAL
BLOCK MARKED 'POS' 'POS' '-''S' WHEN
CONNECTING INTERNAL OR EXTERNAL
ELECTRICAL CONTROLS.
Fig. 5 Showing 230v input electrical connec-
tion without room thermostat or internal time
clock
(Internal wiring loom for timeclock and link
between = & TA remains)
Fig. 6 Showing 230v input electrical connec-
tion and room thermostat connection (con-
nected between TA & TA) without internal
time clock. (Remove link between = & TA).
Note: room thermostat contact rated at 230v.
Should the room thermostat require a neu-
tral or earth, connect neutral to one of the
terminals marked N, and the earth to the
earthing strip.
Fig. 7 Showing 230v input electrical con-
nection and internal timer without room
thermostat.
Note: DO NOT remove link between ter-
minals = & TA.
Fig. 8 showing 230v input electrical connec-
tion internal timer and room thermostat.
Note:
i) Room thermostat contact rated at 230v.
Should the room thermostat require a
neutral or earth, connect neutral to one of
the terminals marked N, and the earth to
the earthing strip.
ii) Terminal marked = is a spare terminal
used to connect controls. (Remove link
between = & TA )
Fig. 7
Internal
time clock
Fig. 8
Room thermostat
Internal
time clock
Fig. 6
Room thermostat
Fig. 5
To internal
t i m e c l o c k
m u l t i p l u g
c o n n e c t o r
(unused)