Supplied By www.heating spares.co Tel. 0161 620 6677
44
Linea Plus AG
SECTION 10 APPENDIX
Instructions for
(A) Fitting Vokèra 24 Hour Time Switch (Part No. 201)
and Vokèra Digital 7 Day Time Switch (Part No. 202)
(B) Wiring to external Time Switches and Room Thermostat
(C) Wiring for 'S' & 'Y' Plan Installations.
A.
Installation of the Vokèra time switches (24 Hr and 7 Day)
Remove printed circuit board cover (5 screws).
Remove the clock aperture blanking plate (1) fig.1 by
squeezing the 4 lugs on the rear of the plate together and
push the plate out.
Remove the central circular disk from the plate (some
force is necessary to break the holding nibs).
Remove the clock from its box.
Wire the clock as shown in fig. 2. The wiring loom to the
clock comes complete with 4 spade connectors (for
connection to the clock terminals), and a multi-plug for
connection to the clock loom pre assembled on the
appliance.
Replace the clock blanking plate back into the fascia of
the appliance.
Insert the clock into the aperture from the back of the
control panel, and secure the clock to the front control
panel using the four screws provided.
Identify the internal clock wiring loom and disconnect
the end plug. Push fit the multi-plug onto the multi-plug
connector connected to the time clock. The multi-plug
connector is polarised, it is therefore only possible to
connect the multi-plugs one way.
When all electrical connections are made replace printed
circuit board cover.
NO EXTERNAL OR INTERNAL CONTROLS
The loop between terminals = & TA remains when no
external or internal controls are used (as fig. 5).
ROOM THERMOSTAT
Remove the loop between terminals = & TA and
connect room thermostat between TA & TA (as fig. 6).
1
Fig. 1
Blue
Fig. 2
Fig. 4
Fig.3
Spare
White
Brown
1 2
3 4 5
Link 1 &
4 in r/stat
1
2
3
4
5
6
Vokera room
thermostat
Neutral
Live
Load
Red/White
Clock
Multiplug
Connector