13
Linea Plus AG
Mounting the boiler
The fixing holes for the wall-mounting bracket
& jig should now be drilled and plugged, an
appropriate type and quantity of fixing should
be used to ensure that the bracket is mounted
securely. Once the bracket has been secured
to the wall, mount the appliance onto the
bracket & jig.
5.5.3.1
Installation of twin adaptor kit (fig. 15)
•
Remove or discard the flue restrictor ring
from the appliance flue outlet (see fig. 1).
•
Insert the small restrictor ring (supplied with
the twin adapter kit) if the total flue length –
including the allowance for any bends – is
less than 8 metres.
•
Insert the exhaust connection manifold onto
the appliance flue outlet.
•
Place the silicone seal (supplied with twin
adapter kit) over the rim of the exhaust
connection manifold.
•
Remove one of the blanking plates (located
to the left & right of the appliance flu
•
Remove one of the blanking plates (located
to the left & right of the appliance flue outlet)
and – using the same screws – install the air
baffle.
5.5.3.2
Installation of condensate drain kit
(fig. 16)
Fig. 16
Fig. 17
The condensate drain kit must be fitted within
1 metre of the appliance flue outlet. It is
recommended that the condensate drain kit
should be fitted in the vertical plane, however
it can be fitted horizontally with care.
•
Fit the first bend to the condensate drain kit
or exhaust connection manifold by firmly
pushing in to position.
•
Using the two holes in the exhaust connection
manifold as a guide, drill a 3mm hole in each
and secure using the screws provided.
•
Connect the air inlet pipe to the air baffle as
above.
•
The twin flue pipes extensions and
accessories can now be installed by pushing
together (the plain end of each extension or
bend should be pushed approximately 50mm
into the female socket of the previous piece).
The condensate drain trap must be connected
to the drain in accordance with Building
Regulations or other rules in force
5.5.3.3
Horizontal termination ( fig. 17)
The twin flue system must be converted to the
dedicated concentric flue kit for termination.
•
The horizontal terminal is supplied with a
built-in converter box and cannot be
shortened.
•
A 130mm hole is required for the passage of
the concentric terminal through the wall.
Depending on site conditions it may be
preferable to install the terminal assembly
prior to fitting the twin flue pipes.
Mark and drill a 130mm hole for the passage
of the horizontal flue terminal, ensuring that
there is a 1º fall back to the boiler (17mm per
1000mm). Insert the terminal assembly into
the flue hole.
Push-fit the twin flue pipes onto the concentric
to twin converter ensuring that the exhaust
pipe connects to the exhaust connection on
the concentric to twin converter.
If necessary cut the plain ends (male) of the
twin flue pipes to allow connection to the
concentric to twin converter.
Fig. 15