Supplied By www.heating spares.co Tel. 0161 620 6677
20
Linea Plus AG
6.12
Final Check for Operations
Turn mode selector switch to the OFF/RESET
position, disconnect pressure gauge, re-tighten
screw. Relight boiler.
6.12.1
Re-check for gas soundness.
6.12.2
Re examine heating and hot water systems
and cold water supply for water soundness.
6.12.3
Check the appearance of the gas flame to
assess adequacy of combustion air supply.
6.12.4
Re-check the flue system for soundness and
adequacy of supports.
6.13
Concluding Operations
6.13.1
If external/internal controls have been discon-
nected and terminals TA & TA temporarily
linked, remove the link and reconnect the
controls circuit. Check the operation of the
controls.
6.14
Refixing the boiler casing (fig. 24).
6.14.1
Offer up the front casing to the back frame in
a near vertical attitude and locate the hooks on
the casing over the hooks on the frame.
Slide the casing downwards to fully engage
the hooks and to align the bottom fixing holes.
Replace the two case retaining screws (fig.24).
6.14.2
Hinge up the control fascia and secure using
the two screws (fig.25).
6.14.3
Disconnect filling loop, fit filling loop cap. Leave
filling loop in a safe and accessible place.
6.15
Supplementary Instructions for Fitting & Re-
moving Optional Time Clock and for Wiring to
External Controls.
Section 10 Appendices A and B at the rear of
this manual provides full instruction for fitting
and wiring the optional built-in time switches
and for wiring to external controls.
6.16
Complete details of the boiler, controls, instal-
lation and commissioning in the log book
supplied with the boiler. This is an important
document which must be correctly completed
and handed to the user. Failure to install and
commission this appliance to the manufactur-
ers instructions may invalidate the warranty.
SECTION 7 INSTRUCTING THE USER
7.1
Hand over the copy of the Users Instructions
and boiler log book supplied with the appli-
ance, together with these instructions. Explain
how to operate the boiler correctly and how to
use the timeclock and room thermostat if fitted.
7.2
Show the user how to switch off the appliance
and indicate the position of the electric supply
isolator.
7.3
Inform the user of the location of all drain
cocks and air vents.
7.4
Explain how to turn the appliance off for both
short and long periods and advise on the
precautions necessary to prevent damage
should the appliance be inoperative when
freezing conditions may occur.
7.5
Show the user the filling loop position its
function and how to repressurise the system
using the filling/inlet valve.
7.6
Advise the user that, for continued safe and
efficient operation, the appliance must be serv-
iced by a competent person at least once a
year.
Fig. 24
Case Screws
Case screws
(one either side)
Fig. 25