UD101L User Guide Document: UD101L-2
----------------------------------------------------------------------------------------------------------------------------- ---------------
42
➢
There will be some image position shift after system setup. The main reasons are as follows:
-
Thermal drift due to projector internal temperature change. When power on the projector,
the temperature is lower. After 20-30 minutes, the image position shift may be up to 5-
10mm. Different projector will have different thermal drift range.
-
Stability of mounting system.
-
Projector structure change after installation due to weight and thermal effect.
-
Cable connection and cause weight balance issue.
-
Change lamp
-
Earth quake or caused by human reasons.
➢
The first projector image position calibration should be done within one month after installation.
The second calibration may be required after 3 months, then every 6 months or once a year.
➢
If user finds big position shift and doesn’t know the real issue. Please follow below procedures
to confirm the issue is from GeoBox or not.
-
Turn off GeoBox and open projector internal test pattern.
-
Mark the corner positions of the projector image.
-
Check projector image shift condition after some time with GeoBox in OFF condition.
-
User will clearly identify that the position shift is from GeoBox or not after this procedure.
-
GeoBox is digital processor and will not change image position only for few pixels.
11.5. System crash and malfunction
➢
After FW update, please reset the system through a pin inserting to reset hole on the back
panel for 5 seconds to avoid abnormal settings inside the system.
➢
When the input source is 4:4:4 PC graphics signal, only [Brightness], [Contrast] and
[Sharpness] three items under [Picture] menu can be executed. If the input is 4:2:2 video
source, all the items are functional.
➢
When implement [Corner Wall] alignment, other geometry functions will be not functional.
➢
Remote controller may be interfered by environment and can’t be smoothly operation.