RS-232 Error Codes
If an errcode ? command returns one of the following values, you have encountered a
likely system error requiring the attention of a qualified service technician. Try resetting the
projector by powering it off, allowing it to cool and powering it on again.
The specific code number identifies the source of the error detected, and is particularly
useful in cases where the projector is far away. For example, the code “7” means that Fan
1 has failed.
Error Code
Description
0
Inlet NTC thermal sensor is over temperatuer.
1
Color wheel NTC thermal sensor is over temperature.
2
Lamp 1 over temperature
3
Lamp 2 over temperature
4
Ballast 1 over temperature
5
Ballast 2 over temperature
6
Fans error when system power on.
7
Fan1 locked
8
Fan2 locked
9
Fan3 locked
10
Fan4 locked
11
Fan5 locked
12
Fan6 locked
13
Fan7 locked
14
Fan8 locked
15
DDP3021 communication fail when system power on
16
Lamp ignited fail 3 times when system power on
17
Lamp shut down while system is working
18
Ballast UART communication fail
19
PCF8575 external GPIO communication fail, it can crash system.
20
Lamp door was opened.
21
GENNUM SPI communication fail when system power on.
22
System hardware I2C communication fail, it can crash system.
23
System software I2C communication fail.
24
Temp sensor error.
25
check sum of EEPROM error.
26
check sum of EDID error.
27
Check version of EEPROM fail.
28
Gennum Reset.
29
Osd load error.