ENGLISH
Access to memory cells
-
Switch on the unit by slight knock at the case.
- If “
0.0 kg”
or “
0.0 lb”
are displayed,
stand on
the scales barefoot, your feet and heels should
be fitted into the circles. Wait until your weight
is displayed.
-
Keep staying on the scales.
When the “
0000
”
symbols are displayed
and begin to disappear
gradually, the percentage of fat and water,
muscles and bone mass in body tissues is be-
ing measured.
- After measurements the following data will
be displayed: - percentage of fat “
fat”
, water
“
TBW”
, muscles “
MUS”
, bone mass “
BONE
”,
as well as daily demand in kilocalorie “
KCAL
”.
The results will be repeated three times in this
sequence.
- Estimation of the results is reflected by color
indication; – red arrow means excess weight,
yellow sector – normal weight, green arrow
– underweight.
- Then weight indications and percentage of fat
are recorded into the memory cell of the user,
which is displayed by gradually decreasing
“
0000”
, “
.
000 - …0”
.
- At gradually decreasing of “
0000”
, “
.
000 -
…0”
, you can refer to the necessary memory
cell.
- Use “
/
” to select user “
P0, P1…P9”
, and
press “
ENTER”
to confirm.
- After it the results of the previous measuring
will be displayed (weight and fat percentage),
color indicators (red arrow means excess
weight, yellow sector – normal weight, green
arrow – underweight) will not light up.
- Then gradually decreasing “
0000”
, “
.
000 -
…0”
will appear on the display, and the scales
will switch off.
Note:
- Access to memory cells is possible only at the
moment of recording of current measuring in-
dications at gradually decreasing “
0000”
, “
.
000 - …0”
on the display.
- If in one of the memory cells (for instance,
“P5”)
there are no data about weight and fat
percentage, it is impossible to recall indica-
tions from the cell (for instance
“P6”)
.
- If the unit operates unstable, check the batter-
ies and replace them if necessary.
MAINTENANCE
• Take care using the scales. This is the preci-
sion tool, avoid temperature differences, high
humidity, strikes, dust and direct sun rays.
• Keep away from heaters.
• Do not jump on the scales.
• Wipe the platform with damp cloth.
• Do not use chemicals and abrasive agents to
clean the scales.
• Do not let liquids inside the housing of the
scales.
• Do not use or keep the scales in humid (more
then 80%) cabinets, do not let it to contact
with water or other liquids, as such a contacts
could affect the measurement accuracy or
lead to scale malfunction.
• If you do not use the appliance for a long time,
open the battery compartment lid and remove
the batteries.
• Keep the appliance in a dry place out of the
reach of children.
SPECIFICATIONS
Max.weight: 180 kg
Min.weight: 2 kg
Divisions: 0,1 kg
Battery: 2 batteries 3V CR 2032
Specifications subject to change without prior
notice.
Service life of appliance - 5 years
GUARANTEE
Details regarding guarantee conditions can be
obtained from the dealer from whom the appli-
ance was purchased. The bill of sale or receipt
must be produced when making any claim under
the terms of this guarantee.
This product conforms to the EMC-
Requirements as laid down by the
Council Directive 89/336/EEC and
to the Law Voltage Regulation (73/23
EEC)
1978.indd 5
1978.indd 5
28.01.2010 15:05:03
28.01.2010 15:05:03
Summary of Contents for VT-1978
Page 1: ...1978 indd 1 1978 indd 1 28 01 2010 15 05 01 28 01 2010 15 05 01...
Page 46: ...BEL 0606 2006 UZ 0606 2006 1978 indd 46 1978 indd 46 28 01 2010 15 05 06 28 01 2010 15 05 06...
Page 47: ...1978 indd 47 1978 indd 47 28 01 2010 15 05 06 28 01 2010 15 05 06...
Page 48: ...1978 indd 48 1978 indd 48 28 01 2010 15 05 06 28 01 2010 15 05 06...