PowerDome Installation Manual
PTZ and Dome Installation
3.3 S
ETTING THE
S
ITE
A
DDRESS
DIP S
WITCH
The receiver card mounted on the PowerDome’s pan/tilt assembly contains a multi-position DIP switch.
See Figure 47. Use the switch to assign a camera number to the PowerDome.
Receiver card
Site address DIP switch
Figure 47. Location of site address DIP switch
To program the receiver’s site number on the DIP switch see Table 2 and Appendix C.
Table 2. DIP switch positions and equivalent values
DIP
Switch
Position
Number 1 2 3 4 5 6 7 8 9 10 11 12
Equivalent
Value
1 2 4 8 16 32 64
128
256
512
X X
X = Not Used
If you use the PowerDome with coaxial UTC telemetry, we recommend that you set the address
especially if you plan to add a VPD-ALM16 alarm module.
If you use RS485 directly from a Vista NPX/KBD/J3De or VPD-KBD keyboard that is also controlling
multiple Vista Triplex Columbus digital recorders or VDC1604 matrix units, address domes attached to
the units as follows:
Unit with BaxNet address 1: 1 through 16
Unit with BaxNet address 2: 17 through 32
Unit with BaxNet address 3: 33 through 48
Unit with BaxNet address 4: 49 through 64
For units with any other BaxNet address, domes should be numbered 1 through 16 and you should use
only one keyboard.
When you use UTC control, each receiver needs to tune to the transmitter. Select each dome in turn, and
pan left and right until the dome moves. This should take about 5 to 10 seconds.