Chapter 6: Data Details Tables
DE5450S Remote Programmer Guide Rev. 8
43
Condition Description
disconnected.
COMMUNICATION
FAILURE
Communication failure between the control panel
and the monitoring station.
TAMPER OPEN
Control panel has been opened or tampered
with.
JAMMED
TROUBLE
Control panel transmissions are being jammed.
TAMPER ALARM
Control panel has been opened or tampered
with. The alarm. The alarm state ends only after
disarming and then rearming the system.
OTHERS
Other system faults.
PROTOCOL
VERSION
System’s communication protocol version.
6.20 Event/History Log
The Event Log displays the different events that the control panel has detected,
together with their details. The Remote Programmer stores up to 100 events. This
table includes: event number; relevant zone or user number/code; relevant zone
name; type of event; date and time.
The History Log displays up to 1000 different events that the control panel has
detected and stored in a different folder.
Available in PowerMax only: Performing Full Upload will automatically load the Event Log.
Available in P only:
When communicating at the speed of 9600 bps (via serial or GSM digital communication), the Remote
Programmer loads all the data.
When communicating at the speed of 300 bps (via PSTN or GSM analog communication), you need to perform
Upload Table to load the data.