Chapter 6: Data Details Tables
DE5450S Remote Programmer Guide Rev. 8
35
6.11 Zone Enrollment
This table is applicable to the PowerG models.
This table displays information about the enrollment status and diagnostic quality
of the various wireless zones registered in the system. The information includes
the zone number, device installed in the zone and RF ID, enrollment status, the
zone type (
Contact
;
Motion
;
Smoke
, etc.), received signal strength indication (24-
hour and current RSSI) quality of the device (
Strong
;
Good
;
Poor
; or
Not OK
),
device configuration, walk-test and a temperature walk-test.
6.12 Siren Enrollment
A siren is a two-way wireless unit which emits a loud siren and flashes a
bright light in the event of a burglary.
This table displays information about all installed sirens and their enrollment status.
For PowerG installations, the data also includes the siren number and RF ID, the
siren type, received signal strength indication (24-hour and current RSSI) quality of
the device (
Strong
;
Good
;
Poor
; or
Not OK
), device configuration and walk-test.
6.13 Keyfob Enrollment
A Keyfob transmitter is a multi-button wireless unit. They enable the carriers to
perform certain system functions quickly without using the keypad, and therefore
improve system efficiency.
In order that the control panel and the Remote Programmer will recognize the
Keyfob transmitters, each one must be enrolled in the system, and assigned a
keyfob number in the panel. Keyfob initiated events are subsequently identified
and registered with reference to these numbers.
In the PowerCode version, this table displays the keyfob ordinal number, the name
of the user carrying this transmitter, an indication whether the keyfob has been
enrolled, the keyfob ID, the keyfob sync. counter and the keyfob sync. backup.
In the PowerG version, this table displays information about all system keyfobs and
their enrollment status. For PowerG installations, the data also includes the keyfob
number and RF ID, the keyfob type, received signal strength indication (24-hour
and current RSSI) quality of the device (
Strong
;
Good
;
Poor
; or
Not OK
), device
configuration and walk-test.