Default Setting: ‘1.None’
This option is available when connecting the Slave Reader using the card or fingerprint to the
terminal in order to use as a secondary authentication device. The mode is set to ‘2’ when
connecting the Wiegand card reader, and ‘3’ when connecting the SR100.
Press [ENT] button to move to the next setting.
Default Setting: ‘2.No’
When setting to ‘1.Yes’, the Anti-Passback in the terminal
is checked.
This screen is displayed only when <Ext Device> is set to ‘2’ or ‘3’.
This option is used to allow only authorized users to access and leave the office. To this end, the
terminal and Slave Reader are installed to both the inside and outside of the door. Only users
who access the office by authentication via the terminal can leave the office by authentication
via the Slave Reader. When setting ‘1.Yes’, the server authentication is unavailable. The device
checks whether Passback is valid in the authentication order between the terminal and the Slave
Reader.
Press [ENT] button to move to the next setting.
Default Setting: ‘0’
This option is to set the authentication (T&A) mode saved from the Slave Reader. If the device
is set to '0', it is saved as the current authentication mode; saved to F1 when ‘1’, F2 when ‘2’,
Access when ‘3’, F3 when ‘4’, and F4 when ‘5’.