Chapter 4 Deployment CPU 313SC/DPM
HB140E - CPU SC - RE_313-6CF03 - Rev. 07/45
4-9
•
Establish a network connection between Ethernet PG/OP channel of the
CPU and PC.
•
Start the SIMATIC Manager from Siemens and create a new project.
•
Add a new System 300 station via
Insert
>
Station
>
SIMATIC 300-
Station
.
•
Activate the station "SIMATIC 300" and open the hardware configurator
by clicking on "Hardware".
•
Engineer a rack (SIMATIC 300 \ Rack-300 \ Profile rail)
•
Place the Siemens CPU 313C-2DP with the order no. 6ES7 313-6CF03-
0AB0 V2.0 from the hardware catalog. This may be found at SIMATIC
300 \ CPU 300 \ CPU 313C-2DP.
•
Include the CP 343-1EX11 at slot 4 (SIMATIC 300 \ CP 300 \ Industrial
Ethernet \ CP 343-1).
•
Type the wanted IP address and subnet mask into the dialog window of
"Properties" of the CP 343-1 and connect the CP with "Ethernet".
•
Save and compile your project.
•
Transfer your project via MPI or MMC into your CPU. More information
about transfer methods may be found in the chapter "Project transfer".
Direct after the assignment the Ethernet PG/OP channel may be reached
by the Siemens SIMATIC manager by means of these IP address
parameters and the
Access Path
"TCP/IP -> Network card .... Protocol
RFC 1006".
Initialization via
minimal project