Manual VIPA System 300S SPEED7
Chapter 5 Deployment I/O periphery
HB140E - CPU SC - RE_313-6CF03 - Rev. 07/45
5-29
Effect at pulse at comparison value with pulse duration Zero
8
7
6
5
4
3
2
1
0
Comparison value
Hysteresis
Output:
Hysteresis = 0
Hysteresis = 3
Counter value
1
2
3
4
5
6
7
1
Counter value
=
comparison value
→
output is set and hysteresis activated
2
Leave hysteresis range
→
output is reset and counter value
<
comparison value
3
Counter value
=
comparison value
→
output is set and hysteresis activated
4
Output is reset for leaving hysteresis range and counter value
>
comparison value
5
Counter value
=
comparison value
→
output is set and hysteresis activated
6
Counter value
=
comparison value and hysteresis active
→
output remains set
7
Leave hysteresis range and counter value
>
comparison value
→
output is reset
With reaching the comparison condition the hysteresis gets active. At
active hysteresis the comparison result remains unchanged until the
counter value leaves the set hysteresis range. After leaving the hysteresis
range a new hysteresis is only activated with again reaching the
comparison conditions.