![Vimar VIGAS 100 Installation & Assembly Manual Download Page 27](http://html1.mh-extra.com/html/vimar/vigas-100/vigas-100_installation-and-assembly-manual_1026937027.webp)
27
Gasifying boilers VIGAS
15.2 Discharge fan
The discharge fan “2” is designed to discharge boiler waste gases
from the gasification chamber during the adding of fuel into the
log magazine. Its recommended to add discharge fan if you do
not meet parameters „A“ and „B“.
Its mounted between chimney neck and chimney. Capacitor „3“ is
mounted aboard of the boiler. Electricaly connect to control board
AK 3000S. Its suppleid in two sizes in accordance of chimney
neck.
V25 – for boilers VIGAS 16, VIGAS 25, VIGAS 29 UD
V80 – for boilers VIGAS 40, VIGAS 60, VIGAS 80, VIGAS 100
15.3 Pump
AK 2000 electronic regulation, in its basic equipment,
allows to connect one circulation pump. Pump control
is depend on boiler water temperature and from
selected scheme. Advantage is the pulse control of
pump bolier protection against low-temperature
corrosion. Its recommend, in connection with ladomat to
set hydraulic scheme with
storage tank, in acc. Chapt.
14.2
Breaker 0,8 A
Max. input 180 W
15.4 Indoor thermostat
Comfort is increased with indoor thermostat connection. Indoor
thermostat is connected to mother board AK 3000S. Jumper is on T3
contact, standardly. Contact is switching, no voltage.
When T3 contact is disconnect, „OFF“ indicate on display. Fan will be
disconnected. Boiler status is indicated by
symbol. After reclosre,
boiler is in „ON“ mode and boiler is activated.
Warning:
If indoor thermostat is disconnected for longer than 1 hour, then boiler will be blown through for
short time to keep glowing embers.
BOILER TYPE
Min A
Min B
VIGAS 16, VIGAS 25, VIGAS 29 UD
8 m
160 mm
VIGAS 40
8 m
200 mm
VIGAS 60, VIGAS 80, VIGAS 100
12 m
200 mm
Drawning with dimmensions for V25 and V80 available on www.vimar.sk
Summary of Contents for VIGAS 100