Gasifying boilers VIGAS
13. OPERATING INSTRUCTIONS
13.1 Before operation:
13.2 Boiler operation
1. Connect boiler to distributing network (230V/50Hz) by power wire.
2. Wait when dispay will be activated to basic indication:
a) without lambda sensor – immediately,
b) with lambda sensor – 30 sec., approx. ( automatical server initialization).
3. Chapt. 4 – 8 choose the configuration that match to your boiler configuration with accesories,
that will help to control AK 3000.
4. Set the boiler with AK 3000 control to deactvated mode
"Off"
.
5. Fuel
heating:
a) by using the rod open the chimney flap (Pic.3/3),
b) open the upper door (Pic.3/2) on fireproof ceramics (Pic.3/9) put the paper so that
small piece of paper extend to lower burning chamber (Pic.3/25), woodchips, cleft
timber,and fill-up with fuel,
c) close upper door and open slightly lower (Pic.3/13) to start heating the fuel(obr.3/4), in
configuration with discharge fan, the heating will be quicker to activated the fan.
d) close lower door and chimney flap when fuel is burning; 10 – 15 minutes,approx.,
6. Activate the boiler to
„ON“.
Boiler starts to gasyfing and control its output automatically to
set temperature.
7. To refil the fuel follow steps in chap. 4 – 8.
8. To deactivate the boiler, follow steps in chap. 4 – 8.
13.3 Keeping operation and output regulation
Fuel in boiler is moved spontaneously in the direction to fireproof nozzle. Ash falls through
nozzle and deposits in combustion chamber. Boiler output is regulated automatically according to
the set temperature of outlet water. If there is mains failure during a longer period of time or if
automatic regulation fails, it is possible to heat as follows (it is only applicable for the systems of
central heating with gravitation flow): open chimney flap and let bottom door open a little. If this
heating is used, it is necessary to check outlet temperature more frequently and to add less fuel.
The boiler may easily become overheated if the whole fuel bunker is filled.
▪
to be informed with operatong instructions and how to operate the electronic control AK 3000,
▪
to check teh water pressure in the system of cental heating (3 bars. max),
▪
to connect accessories (f.e. pump, discharge fan or indoor thermostat),
▪
to check the placing of fireclay bricks in combustion chamber pic.3,
▪
to check the cover metal sheets,
▪
to check the power to mains (230V/50Hz),
▪
to prepare sufficient amount of fuel for heating and burning.
Burning fuler
Lower door open