Gasifying boilers VIGAS
By
▲
buttons set the parameter you want to edit and by
pressing
„ENTER“
button,
the value starts to flash.
▲
buttons
set requested value.
max
Choose maximal gases temperature that will result in
decreasing the operating speed
end
Choose shotdown temperature of the boiler
λ
Lambda value, that servo-controled flap keeps.
Recommended is 1,35.
„
“
Increase or decrease the value, maximal output will be
changed. Is adviced to decrease the value in transition
period (boiler tar level will drop).
Â
Brightness
Roll
Press „yes“ will acitivate the value rolling (Pic.7/2)
Help 0s
Set the time when graphical control will be indicated
8.1.5 Boiler disconnection (automatically)
8.2 PARAMETERS SETTING VIGAS
Lambda Control
BOILER AND VIGAS BOILER
WITH GASES THERMOMETER
9. TIME SETTING
Set time and date, when boiler is pluged first time. In left corner is time is indicated.
When gases temperature drops under the set temperature
(
end) (boiler is switch-off automatically). „END“ will be
indicated on the display. Servo-controled flap will be moved to
position (servo 0%). In this position secundary air is closed as
well as primary air. By pressing „ENTER“ boiler will start
operating again.
To call parameters setting
hold „ENTER“
button at any boielr status
and by pressing
▲
button.
„ENTER“
To call parameters setting
press longer „ENTER“
button at any
boielr status and by pressing
▲
button twice.
By
◄
button set date or time, that will be edited.
▲
buttons
choose date and time. Button
►
will exit the settings
.
Mon – Monday, Tue – Tuesday, Wed – Wednesday, Thu –
Thursday, Fri – Friday, Sat – Saturday, Sun – Sunday