Gasifying boilers VIGAS
12.3 Service settings hydraulic scheme connection
12.4 Service tools
WARNING
The output contol of the pump will be changed by hydraulic
connection. It is important, that software setting of hydraulic pump
match the setting of the boiler in connection with central heating
system. Basic memory of control contains 4 schematics. It is
possible to add more schematics if necessary. Schematics that are
used for additional module „EXPANDER“ are delivered on mini
SD card, or will be available on
www.ers.sk
, free to download,
through PC to memory card that will be inserted to the module of
the boiler control (Chapt.13).
If necessary, is it possible to return to last scheme to press
„last“
Continue Chapt.14
7. Press
„ENTER“
, scheme 1 indicates on the display
8. Buttons
▲
choose requested scheme and press ENTER.
9. Button „ENTER“ confirm „Yes“ – to save scheme
10. To exit use
►
button
Scheme 1 :
Scheme is dedicated for boiler with storage tank. „LADOMAT“
provides reverse water protection. Pump is connected to boiler
control and working over 40
o
C. Requested temperature is possible
to set up to 90
o
C. T3 contact on mother board AK 3000 S is used
for connection to thermometer PT 1000, which is able to measure
temperature in stogare tank.
Warning: It is not possible to connect indoor thermostat to T3
contact.
Scheme 2 :
Scheme is dedicated to central heating systems, where reverse
water protection provides external control system. Pump is
connected to the control and it is working pulse in dependence of
boiler water temperature. T3 contact on mother board is used to
connect indoor thermostat.
Scheme 3 :
Scheme with 3-way thermostatic valve. Pump is connected to the
control and it is working pulse in dependence of boiler water
temperature. T3 contact on mother board is used to connect indoor
thermostat.
Scheme 4 :
Scheme is set as a standard. Pump is connected to the control and
it is working pulse in dependence of boiler water temperature. T3
contact on mother board is used to connect indoor thermostat.
Funcionality of each system can be check in service settings by