Gasifying boilers VIGAS
6.1.2 Boiler activated – heating mode
6.1.3 Boiler activated – burning mode
6.1.4 Adding fuel, Disconnection the boiler (manually)
5.1.6 Disconnection
the
boiler (Automatically)
Boiler is set to heating mode, if outgoing gases temperature is
lower, then set minimal gases temperature (
end). Minimal gases
temperature, as well as, maximal gases temperature can be set in
boiler settings. Minimal gases temperature is set on 90°C, maximal
gases temperature is set on 200°C, which are standard settings.
Pump is
pulse
working in dependence on temperature of the boiler
water!
The burning mode is active after the gases temeprature is higher
(
end) + 20
0
C. In this mode pump is working
pulse
(bolier
protection against low-temperature corrosion). The pump is
working, when symbol flash. Boiler is responsive to indoor
thermostat, when indoor thermostat is switched off boiler slowly
decreasing its output.
Choose one option
OFF Switch off
Add fuel
⌧
Cancell the control
bc
Change the indicated value
By pressing „
“ fan is swithed off and discharge fan is
automatically activaed on 300s. In left corner is running time of
discharge fan. If „+60“ is chosen, new graphical control is indicated.
By using the rod open the chimney flap, consequently open the
upper door. You can add fuel, if necessary. Close the upper door
and chimney flap. By pressing „0“ discharge fan is swithed off. By
pressing adding fuel is finished, discharge fan is switched off
automatically and fan will switched on.
When gases temperature drops under the set temperature
(
end) (boiler is switch-off automatically). „END“ will be
indicated on the display. By pressing „ENTER“ boiler will start
operating again.
Using graphical control. To call the graphical control, press central button ENTER. Graphical
control offers option to switch off, adding fuel or cancel the graphical control.