18
Gasifying boilers VIGAS
STB
10. HARDWARE AND SOFTWARE INFORMATION
11. ERROR MESSAGES
11.1 STB failure
At „STB“ failure boiler is overheated. Thermal
fuse is activated (Pic.3/21). The fan is
disconnected from voltage. Boiler is activated
again only if „STB“ protection is mechanical
pressed. Boiler is need to be switch-on by
„ENTER“ button.
12. SERVICE SETTINGS PIN 0000 PROTECTED
To call informations setting
hold „ENTER“
button at any boiler
status and by pressing button.
▲
buttons choose modul and confirm „ENTER“. Information
about the module will be indicated on display.
To call error messages
hold „ENTER“
button at any boielr status
and by pressing 3 times. By pressing „ENTER“ error with
description will be indicated on display.
Service settings PIN 0000 protected can be used only in restricted
cases. Only trained service engineer can do these settings. (In
necessary cases client can do also). In service settings are
adjusted boiler type with accessories and hydraulic connection
scheme, etc.
To call the service setting PIN 0000 protected as follows:
1.
Hold „ENTER“
button at any boielr status
2. Press
▲
button
3.
Hold
◄
button for 4s -
„PIN 0000“
will be indicated
4. Press „ENTER“ 4 times
5. Service settings symbol will be indicated on display
6. Press
„ENTER“
and buttons
▲
choose service setting of
boiler type, hydraulic connection scheme, micro SD card,
service operation and press
„ENTER“
.
Summary of Contents for VIGAS 100