31
© 2012 Viking Preferred Service
Control Board
To access control board:
1. Open doors and remove shelves.
2. Remove light bulbs, (see Refrigerator Light Bulb
section, page 30).
3. Insert a screwdriver blade into the slots to
release the control board housing.
4. Drop down the control board housing and
disconnect the wiring.
5. Disconnect wiring ribbon and press tabs to
release control board from housing.
6. Replace or repair as necessary.
7. Reverse procedure to reinstall.
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power to unit using power
switch before servicing. Wires removed during disassembly must be replaced on proper terminals to insure
correct earth ground and polarization. After servicing, reconnect power using power switch.
Tab
Screwdriver
Blade
Slot
Ribbon
Service Diagnostics and procedures–Disassembly