17
© 2012 Viking Preferred Service
Diagnostics
Service Tests
When the Test Mode has been entered, the first test will be for the defrost test.
101 Defrost heater and Defrost Circuit
Press the refrigerator temperature “+” (up) or “–” (down) keypad to energize or de-energize the defrost
circuit. The display will read OFF when de-energized as shown below.
op
when energized with open defrost
thermostat and
Cl
when energized with closed defrost thermostat.
102 Compressor/Condenser Fan
Press the refrigerator temperature “+” (up) or “–” (down) keypad to toggle Compressor/Condenser fan ON
and
OFF.
112 Freezer Fan
Press the refrigerator temperature “+” (up) or “–” (down) keypad to toggle Freezer Fan OFF, High or Low speed.
note:
Display will show 11.0-14.0 volts for HIGH and 7.75-8.25 volts for LOW. When off 0.0 will be displayed.
1 0 1
O F F
Press either button to toggle
through test cycles
Press either button to
cycle defrost On and Off
1 0 2
O F F
Press either button to toggle
through test cycles
Press either button to cycle
compressor and condensor
fan motor ON and OFF
1 1 2
O F F
Press either button to toggle
through test cycles
Press either button to cycle
freezer fan OFF, High or
Low speed