E.  Quick Programming Features

A  one  or  two  digit  door  strike  code  can  be  entered  by 
programming position 

#41

. When in programming, enter the 

one or two digit code followed by “

#41

”. 

Note:

  “

Q

” and “

#

” 

can be entered as valid characters of the door strike code by 
substituting “#20” and #21” (respectively) when programming 
the door strike code (see section 

D

).

 To  disable  the  door 

strike  relay,  enter  “

#41

”  without  any  preceding  numbers. 

Examples of door strike code entries are shown to the right.

H.  Door Strike Code

Description

Enter Digits

+ Location

Speed dial numbers  .................................................................................................................

0-46 digits**

+ #01

 -

 #12

Door strike time in sec (factory 05, 00 =.5 sec)*........................................................................

2 digits

+  #40

Door strike code (factory 6, no digits disables) .........................................................................

1-2 digits

+  #41

Maximum call time in min (factory 3, 0 = .5 min, no digits disables)*  ......................................

1 digit

+  #42

Maximum ring time in sec (factory 20, 00 disables)*  ...............................................................

2 digits

+  #43

Silence Time Out in sec (factory 10, 00 disables)*   .................................................................

2 digits

+  #44

Talk/listen delay time in .1 sec (factory 2)*  ..............................................................................

1 digit

+  #45

Security code (factory 845464)* ...............................................................................................

6 digits

+  #47

Access code (factory set to 123456)* .......................................................................................

1-6 digits

+ #48

Keyless entry codes ..................................................................................................................

1-6 digits

+  #50 - #99

Dial a (

Q

)  ..................................................................................................................................

#20

Dial a (#)  ...................................................................................................................................

#21

Add a 4 second pause  .............................................................................................................

#22

Add a 1 second pause  .............................................................................................................

#23

Second phone number selector  ...............................................................................................

#24

Normal dialing speed (factory setting)  .....................................................................................

#30

Fast dialing speed .....................................................................................................................

#31

Hang up on dial tone enable (factory setting)  ..........................................................................

#32

Hang up on dial tone disable  ...................................................................................................

#33

Disable tenant initiated entry (factory setting) ...........................................................................

#37

Enable tenant initiated entry .....................................................................................................

#38

Reset all programming to factory default settings  ...................................................................

###

Hang up from programming .....................................................................................................

##7

* Cannot contain “

Q

“ or “#“ 

(see #20 and #21)

      ** 

45 digits maximum if two numbers are programmed in one memory location

 

Notes:

1. A single or double beep indicates a valid entry, three beeps indicate an error.  
2. 

 “

Q

“ or “#“, pauses or second phone number selector occupy one digit of memory.

The 

K-1270

 is programmed through the incoming phone line. The programming commands are structured so 

that they do not interfere with the commands of a 

C-1000B

 controller

.

The 

K-1270

  Entry  Controller  can  be  programmed  with  up  to  twelve  46  digit  numbers.  Each  number  can  also  be 

programmed with special features such as pauses, and the Touch Tones “

Q

” and “

#

”. Each of the special characters count 

as a single digit. Each of the speed dial positions 

#01

 to 

#12

 pertain to the corresponding button on the front of the 

K-

1270

. The button “

0

” uses position 

#10

, the “

Q

” uses position 

#11

 and the “#” uses position 

#12

. To program a speed dial 

position, enter programming (see section 

A

) then enter the desired number followed by the selected position. To clear a 

position, only enter a “

#

“ followed by the position number with out any preceding number.  

The 

K-1270

 also has the capability to dial a second phone number if there is no answer or busy at the first number. This 

can be used if the tenant wants the visitor to call their cell phone if they are not at home. To program a second number, be 
sure that position 

#43

 is programmed with the desired maximum ring time, then enter the first number to be dialed, followed 

by “

#24

”. A single beep should be heard. Next enter the second number to be dialed followed by “#“ plus the memory 

location. The total number of digits cannot exceed 46 for each position (45 digits if two numbers are programmed). The 
following are examples of speed dial number entries: 

F.  Speed Dial Numbers

To Program the K-1270 to...

Step 1 (see section A)

Step 2 - Enter Digits

...store 555-1234 at the first button position

Enter programming

5551234#01

...store a 9, a 1 second pause, then 333-4444 in the seventh button position

Enter programming

9#233334444#07

...store a 23

Q

# in the eight position

Enter programming

23#20#21#08

...store a first number of 22 and a second number of 33 in the “#“  
   button position

Enter programming

22#24 

(beep) 

33#12

The actual time the door strike relay is energized is controlled by location 

#40

. The time can be set from 00 to 99 seconds, 

(an entry of “00” gives 0.5 seconds). In order to use this feature, be sure the relay door strike code is set (see section 

H

).

G.  Door Strike Time

To Program the  

Door Strike Code to...

Step 1 

(see section A)

Step 2 

Enter Digits

“99”

Enter programming

99#41

“3”

Enter programming

3#41

QQ

Enter programming

#20#20#41

“#1”

Enter programming

#211#41

Q

Enter programming

#20#41

Summary of Contents for K-1270 Series

Page 1: ...Mylar speaker Self draining mic mount Faceplate keypad mic and speaker gaskets Designed to meet IP66 Ingress Protection Rating see DOD 859 Operates on 12 to 24 volts AC DC 12 speed dial buttons 22 digits each 12 alternate number positions 22 digits each One button operation no call button Hang up on CPC busy silence time out or dial tone Touch tone restriction from microphone Integral relays for c...

Page 2: ...c Die cast with Satin Chrome Finish internally sealed per IP67 Speaker Screen Speaker screen with 0 018 wide slots to prevent punctures from paperclips etc Faceplate Material 14 gauge 316 stainless steel with 4 brushed finish Speaker Mylar speaker with rubber gasket to maintain water tight seal and eliminate water deterioration Blue Call LED Lights steady to help locate the button in low light Mic...

Page 3: ...urface mount unit using an optional VE 5x10 The rough in box uses the inner set of four holes on the face plate while the VE 5x10 uses the outside set of holes A set of dummy screws and nuts are provided to fill the unused mounting holes To install a directory remove the four screws that mount the directory lens to the front of the K 1270 using the included Allen wrench Insert a paper directory be...

Page 4: ... more information VIKING VIKING ELECTRONICS HUDSON WI 54016 STAND ALONE DOOR CONTROLLER ENTRY SYSTEM POWER 12V DC MODEL ES 1 1 POWER PROGRAM PHONE LOG BUS 2 3 4 5 GANG PROG 6 7 8 9 WIEGAND DEVICE 10 11 DOOR STRIKE N O 2 1 L H COM N C BLK RED GRN WHT Doorstrike 12V DC Adapter included with ES 1 OR Share power with 12 24V AC DC door strike with 200mA available current or use the included 12V DC adap...

Page 5: ... door strike will energize for the programmed Door Strike Time Note To prevent unwanted radio interference route the connecting wires through the included ferrite core Note The gel filled water tight butt connectors are designed for insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Cut off stripped ends prior to terminating Rear View of the K 1270 CO Line Yellow...

Page 6: ...el C 1000B not included Doorstrike Magnetic Lock 120V AC 120V AC 120V AC D Using the K 1270 with a C 3000 For a No CO installation a Viking C 3000 No CO controller can be used with the K 1270 Note the K 1270 will need to be programmed on a separate CO line or use the Viking DLE 200B The door strike can be controlled by the K 1270 or the internal relay on the C 3000 just be sure to disable the door...

Page 7: ... DC maximum not included Doorstrike Power Supply Doorstrike 1 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 2 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 3 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 4 Entry Point 3 K 1275 K 1275 E Add Relay Control for up to 4 K 1270 75 Proximity Card Readers IMPORTANT Electronic devices are suscepti...

Page 8: ...ing programming If this happens check to see that DIP switch 1 is ON so the unit is set to answer incoming calls Then turn DIP switch 4 ON to allow accessing programming without the security code Call the line attached to the K 1270 With the phone ringing press the 0 button on the K 1270 keypad The K 1270 should answer the line and you should hear two beeps indicating that you are in the programmi...

Page 9: ...p to twelve 46 digit numbers Each number can also be programmed with special features such as pauses and the Touch Tones Q and Each of the special characters count as a single digit Each of the speed dial positions 01 to 12 pertain to the corresponding button on the front of the K 1270 The button 0 uses position 10 the Q uses position 11 and the uses position 12 To program a speed dial position en...

Page 10: ...eration for a functional description of this feature Tenant Initiated Entry is disabled by default To enable it enter programming see Programming section A Enter 38 Also DIP switch 1 must be turned ON and left in this position to enable the K 1270 to answer incoming calls To disable Tenant Initiated Entry enter 37 Security considerations with Tenant Initiated Entry The K 1270 door entry system is ...

Page 11: ...ess code following the single beep hear two acknowledgement beeps and then either let the visitor in using the doorstrike code or hang up to terminate the call A double beep after the unit answers indicates both that Tenant Initiated Entry is enabled and that the access code is disabled so the user can let the visitor in using the doorstrike code without having to enter the access code or terminat...

Page 12: ...stance Monday 8am 4pm and Tuesday through Friday 8am 5pm central time So that we can give you better service before you call please 1 Know the model number the serial number and what software version you have see serial label 2 Have your Product manual in front of you 3 It is best if you are on site RETURNING PRODUCT FOR REPAIR The following procedure is for equipment that needs repair 1 Customer ...

Reviews: