Features

The

 K-1270

 Entry Phone is a two-way, handsfree 

telephone  with  12  buttons  for  calling  individual 
residences  in  an  apartment  building  with  an 
integrated 125 KHz Proximity Card Reader. The 
rugged  stainless  steel  faceplate  has  a  printed 
directory housed in a waterproof, scratch-resistant 
lens. Each button is beside the tenants name in the 
directory so there are no confusing codes to deal 
with.  Calling  a  particular  tenant  is  as  easy  as 
pressing a single button. The 

K-1270

 has a built in 

speed  dialer  that  can  handle  up  to  12  primary 
phone numbers, each with 22 digits. If there is no 
answer at the first number, a second number can 
be called automatically. Once the tenant answers 
their  phone,  a  single  touch  tone  command  can 
activate the door strike relay. For “no phone line” 
applications,  the 

K-1270

  is  compatible  with  the 

C-3000

 no CO (phone line) controller.  

The 

K-1270-EWP

 shares all of the features of the 

K-1270

  in  addition  to  Enhanced  Weather 

Protection (EWP) for outdoor installations where 
the  unit  is  exposed  to  precipitation  or 
condensation. EWP products feature foam rubber 

•  Built-in 125KHz 26-bit Wiegand proximity card reader with LED, 

beep card read confirmation, and EWP board protection 

•  Compatible with the following Viking Proximity Cards and Fobs: 

PRX-C

PRX-C-ISO

 and 

PRX-FOB (DOD# 198) 

•  

Vandal Resistant Features:

 14 gauge louvered 316 stainless 

steel faceplate with permanent laser etched graphics, heavy duty 
metal keypad and T-10 Torx   Security mounting screws. 

•  

Weather Resistant Features:

 Marine grade 316 stainless steel 

faceplate and screws. Internally sealed keypad. Mylar speaker. 
Self-draining mic mount. Faceplate, keypad, mic and speaker 
gaskets.  

•  Designed to meet IP66 Ingress Protection Rating (see 

DOD 859

•  Operates on 12 to 24 volts AC/DC 
•  12 speed dial buttons (22 digits each) 
•  12 alternate number positions (22 digits each) 
•  One button operation (no call button) 
•  Hang up on CPC, busy, silence, time-out or dial tone  
•  Touch tone restriction from microphone 
•  Integral relays for camera control and door strike 
•  Works with 

C-1000B

 for increased security 

•  Works with 

C-3000

 for “No CO” (phone line) operation 

•  50 keyless entry codes 
•  See model 

K-1205

 for integral camera 

•  Postal lock input 
•  Optional 

VE-5x10

 surface mount box, sold separately (

DOD 424

)

•  Small apartment buildings 
•  Professional buildings 
•  Gated communities

Power: 

12 to 24 Volts AC or DC, 12VDC adapter provided 

Proximity Card Reader Power:

  5 to 14V DC @ 60mA maximum 

 

Note: 

To assure operation during a power outage, a UPS 

should be used.

 

Dimensions: 

127mm x 254mm x 63.5mm (5" x 10" x 2.5") 

Shipping weight: 

2.2 kg (4.8 lbs.)

 

Standard K-1270 Environment: 

-34° C to 65° C (-30° F 

to 150° F) with 5% to 95% non-condensing humidity 

K-1270-EWP Environment:

 -34° C to 65° C (-30° F to 

150° F) with up to 100% condensing humidity 

Relay Contact Rating:  

     Door Strike:  5A @ 30VDC/250VAC maximum 
     Camera:  0.5A @ 125 VAC, 1.0A @ 30VDC 

Connections: 

(16)  gel-filled  butt  connectors  (3M 

Scotchlok UR2)

Applications

Specifications

www.vikingelectronics.com 

Information: (715) 386-8861

    VIKING

gaskets and boots, sealed connections, gel-filled 
butt connectors, as well as urethane or thermal 
plastic potted circuit boards with internally sealed, 
field-adjustable trim pots and DIP switches for easy 
on-site programming.

12 Button Apartment Entry Phone with Built-In 

Door Strike Relay and Proximity Card Reader

“Brushed 316 Stainless Steel” 

(similar to brushed nickel)

K-1270 Series

 

Entry Phones with Keypads 

and Proximity Card Readers

 

July 5, 2017

(shown in optional  

VE-5x10-SS, not included)

Summary of Contents for K-1270 Series

Page 1: ...Mylar speaker Self draining mic mount Faceplate keypad mic and speaker gaskets Designed to meet IP66 Ingress Protection Rating see DOD 859 Operates on 12 to 24 volts AC DC 12 speed dial buttons 22 digits each 12 alternate number positions 22 digits each One button operation no call button Hang up on CPC busy silence time out or dial tone Touch tone restriction from microphone Integral relays for c...

Page 2: ...c Die cast with Satin Chrome Finish internally sealed per IP67 Speaker Screen Speaker screen with 0 018 wide slots to prevent punctures from paperclips etc Faceplate Material 14 gauge 316 stainless steel with 4 brushed finish Speaker Mylar speaker with rubber gasket to maintain water tight seal and eliminate water deterioration Blue Call LED Lights steady to help locate the button in low light Mic...

Page 3: ...urface mount unit using an optional VE 5x10 The rough in box uses the inner set of four holes on the face plate while the VE 5x10 uses the outside set of holes A set of dummy screws and nuts are provided to fill the unused mounting holes To install a directory remove the four screws that mount the directory lens to the front of the K 1270 using the included Allen wrench Insert a paper directory be...

Page 4: ... more information VIKING VIKING ELECTRONICS HUDSON WI 54016 STAND ALONE DOOR CONTROLLER ENTRY SYSTEM POWER 12V DC MODEL ES 1 1 POWER PROGRAM PHONE LOG BUS 2 3 4 5 GANG PROG 6 7 8 9 WIEGAND DEVICE 10 11 DOOR STRIKE N O 2 1 L H COM N C BLK RED GRN WHT Doorstrike 12V DC Adapter included with ES 1 OR Share power with 12 24V AC DC door strike with 200mA available current or use the included 12V DC adap...

Page 5: ... door strike will energize for the programmed Door Strike Time Note To prevent unwanted radio interference route the connecting wires through the included ferrite core Note The gel filled water tight butt connectors are designed for insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Cut off stripped ends prior to terminating Rear View of the K 1270 CO Line Yellow...

Page 6: ...el C 1000B not included Doorstrike Magnetic Lock 120V AC 120V AC 120V AC D Using the K 1270 with a C 3000 For a No CO installation a Viking C 3000 No CO controller can be used with the K 1270 Note the K 1270 will need to be programmed on a separate CO line or use the Viking DLE 200B The door strike can be controlled by the K 1270 or the internal relay on the C 3000 just be sure to disable the door...

Page 7: ... DC maximum not included Doorstrike Power Supply Doorstrike 1 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 2 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 3 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 4 Entry Point 3 K 1275 K 1275 E Add Relay Control for up to 4 K 1270 75 Proximity Card Readers IMPORTANT Electronic devices are suscepti...

Page 8: ...ing programming If this happens check to see that DIP switch 1 is ON so the unit is set to answer incoming calls Then turn DIP switch 4 ON to allow accessing programming without the security code Call the line attached to the K 1270 With the phone ringing press the 0 button on the K 1270 keypad The K 1270 should answer the line and you should hear two beeps indicating that you are in the programmi...

Page 9: ...p to twelve 46 digit numbers Each number can also be programmed with special features such as pauses and the Touch Tones Q and Each of the special characters count as a single digit Each of the speed dial positions 01 to 12 pertain to the corresponding button on the front of the K 1270 The button 0 uses position 10 the Q uses position 11 and the uses position 12 To program a speed dial position en...

Page 10: ...eration for a functional description of this feature Tenant Initiated Entry is disabled by default To enable it enter programming see Programming section A Enter 38 Also DIP switch 1 must be turned ON and left in this position to enable the K 1270 to answer incoming calls To disable Tenant Initiated Entry enter 37 Security considerations with Tenant Initiated Entry The K 1270 door entry system is ...

Page 11: ...ess code following the single beep hear two acknowledgement beeps and then either let the visitor in using the doorstrike code or hang up to terminate the call A double beep after the unit answers indicates both that Tenant Initiated Entry is enabled and that the access code is disabled so the user can let the visitor in using the doorstrike code without having to enter the access code or terminat...

Page 12: ...stance Monday 8am 4pm and Tuesday through Friday 8am 5pm central time So that we can give you better service before you call please 1 Know the model number the serial number and what software version you have see serial label 2 Have your Product manual in front of you 3 It is best if you are on site RETURNING PRODUCT FOR REPAIR The following procedure is for equipment that needs repair 1 Customer ...

Reviews: