When a visitor is at the 

K-1270

, they just need to find the name of the tenant they want to visit on the 

directory and press the associated button. The 

K-1270

 will then seize the phone line and speed dial 

the number programmed for that name. When the tenant answers the call, they can let the visitor in by 
entering the Door Strike Code on their telephone keypad. The tenant can converse with the visitor for 
up to 10 seconds after the Door Strike Code is dialed (to verify the visitor has been granted entry). The 

K-1270

 is able to determine if the door strike command is coming from the apartment or the caller, to 

prevent entry using a hand held touch tone dialer. If the tenant chooses not to let the visitor in, they can 
simply hang up the phone. The 

K-1270

 will drop the line when busy, reorder, CPC signals are detected, 

when  programmable  maximum  call  time  out,  silence  time  out,  maximum  ring  timers  expire  or  10 
seconds after a door strike activation. Only the buttons that have a programmed phone number are 
active (except “#” when used for keyless entry). After a button is pressed, and the call is initiated, it can 
be canceled by momentarily pressing any button on the panel. 

If a second number is programmed for the selected tenant, and there is no answer or busy after dialing 
the first number, the 

K-1270

 will hang up, pause, seize the line, and then dial this second number. In 

this manner the call can be routed to a cell phone if the tenant is not at home. The tenant can still let 
the visitor in using the Door Strike Code. 

It is also possible to talk to a visitor before they press a directory button, and to let them in if Tenant 
Initiated Entry has been enabled.  Make sure DIP switch 1 is on (Auto Answer, see section Q), and 
then call the number of the K-1270.  The unit will answer and send a single or double beep.  After a 
single beep, if Tenant Initiated Entry is not enabled the tenant can converse with the visitor but is not 
able to use the doorstrike code to let them in.  If Tenant Initiated Entry is enabled, the tenant can enter 
the access code following the single beep, hear two acknowledgement beeps, and then either let the 
visitor in using the doorstrike code or hang up to terminate the call.  A double beep after the unit answers 
indicates both that Tenant Initiated Entry is enabled and that the access code is disabled, so the user 
can let the visitor in using the doorstrike code without having to enter the access code, or terminate the 
call by hanging up.  

To use the keyless entry feature, momentarily press or press and hold the “#“ key on the 

K-1270

 keypad. 

When momentarily pressed, 1 beep will be heard and if held for 2 seconds (or longer), 2 beeps will be 
heard. In either case, the 

K-1270

 is then ready to accept the keyless code. Continue by entering one 

of the previously programmed keyless codes. The 

K-1270

 will pause a few seconds to make sure there 

are no more keypad entries, and then actuates the Door Strike relay if valid. If an incorrect code is 
entered, the 

K-1270

 will beep 3 times and the user has to start over and enter a correct code.  

If a Postal Lock is used, a momentary closure of the postal lock switch will energize the door strike for 
the programmed Door Strike Time.

11

Two POTs are provided to increase or decrease speaker volume and microphone sensitivity.  In certain noisy 
locations the microphone sensitivity may need to be decreased as shown below.  

Caution: 

 Setting the microphone 

gain too high may cause distorted audio, prevent the distant party from breaking over and inhibit second number 
redialing.

Q.  DIP Switch Programming / Speaker and Microphone Adjustments

Microphone

Sensitivity POT

ON

OFF

1  2  3  4

Speaker

Volume POT

1 2 3

on

4

Turn POTS clockwise to increase 

(as viewed from the back of the board).

Switch Position Description

1

ON

Incoming calls answered (factory setting)

1

OFF

Incoming calls not answered

2 & 3

ON

Audio Detection normal (factory setting)

2 & 3

OFF

Audio Detection more sensitive

4

ON

Learn Mode - Any incoming calls are 
automatically entered into the 
programming mode, no security code 
required. Use this option if you have 
forgotten your security code.

4

OFF

Normal operation mode (factory setting)

Note: 

On some phone lines, busy and ring back tones may be very soft. In these installations, set DIP switches 

2 and 3 to OFF.

Operation

Summary of Contents for K-1270 Series

Page 1: ...Mylar speaker Self draining mic mount Faceplate keypad mic and speaker gaskets Designed to meet IP66 Ingress Protection Rating see DOD 859 Operates on 12 to 24 volts AC DC 12 speed dial buttons 22 digits each 12 alternate number positions 22 digits each One button operation no call button Hang up on CPC busy silence time out or dial tone Touch tone restriction from microphone Integral relays for c...

Page 2: ...c Die cast with Satin Chrome Finish internally sealed per IP67 Speaker Screen Speaker screen with 0 018 wide slots to prevent punctures from paperclips etc Faceplate Material 14 gauge 316 stainless steel with 4 brushed finish Speaker Mylar speaker with rubber gasket to maintain water tight seal and eliminate water deterioration Blue Call LED Lights steady to help locate the button in low light Mic...

Page 3: ...urface mount unit using an optional VE 5x10 The rough in box uses the inner set of four holes on the face plate while the VE 5x10 uses the outside set of holes A set of dummy screws and nuts are provided to fill the unused mounting holes To install a directory remove the four screws that mount the directory lens to the front of the K 1270 using the included Allen wrench Insert a paper directory be...

Page 4: ... more information VIKING VIKING ELECTRONICS HUDSON WI 54016 STAND ALONE DOOR CONTROLLER ENTRY SYSTEM POWER 12V DC MODEL ES 1 1 POWER PROGRAM PHONE LOG BUS 2 3 4 5 GANG PROG 6 7 8 9 WIEGAND DEVICE 10 11 DOOR STRIKE N O 2 1 L H COM N C BLK RED GRN WHT Doorstrike 12V DC Adapter included with ES 1 OR Share power with 12 24V AC DC door strike with 200mA available current or use the included 12V DC adap...

Page 5: ... door strike will energize for the programmed Door Strike Time Note To prevent unwanted radio interference route the connecting wires through the included ferrite core Note The gel filled water tight butt connectors are designed for insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Cut off stripped ends prior to terminating Rear View of the K 1270 CO Line Yellow...

Page 6: ...el C 1000B not included Doorstrike Magnetic Lock 120V AC 120V AC 120V AC D Using the K 1270 with a C 3000 For a No CO installation a Viking C 3000 No CO controller can be used with the K 1270 Note the K 1270 will need to be programmed on a separate CO line or use the Viking DLE 200B The door strike can be controlled by the K 1270 or the internal relay on the C 3000 just be sure to disable the door...

Page 7: ... DC maximum not included Doorstrike Power Supply Doorstrike 1 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 2 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 3 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 4 Entry Point 3 K 1275 K 1275 E Add Relay Control for up to 4 K 1270 75 Proximity Card Readers IMPORTANT Electronic devices are suscepti...

Page 8: ...ing programming If this happens check to see that DIP switch 1 is ON so the unit is set to answer incoming calls Then turn DIP switch 4 ON to allow accessing programming without the security code Call the line attached to the K 1270 With the phone ringing press the 0 button on the K 1270 keypad The K 1270 should answer the line and you should hear two beeps indicating that you are in the programmi...

Page 9: ...p to twelve 46 digit numbers Each number can also be programmed with special features such as pauses and the Touch Tones Q and Each of the special characters count as a single digit Each of the speed dial positions 01 to 12 pertain to the corresponding button on the front of the K 1270 The button 0 uses position 10 the Q uses position 11 and the uses position 12 To program a speed dial position en...

Page 10: ...eration for a functional description of this feature Tenant Initiated Entry is disabled by default To enable it enter programming see Programming section A Enter 38 Also DIP switch 1 must be turned ON and left in this position to enable the K 1270 to answer incoming calls To disable Tenant Initiated Entry enter 37 Security considerations with Tenant Initiated Entry The K 1270 door entry system is ...

Page 11: ...ess code following the single beep hear two acknowledgement beeps and then either let the visitor in using the doorstrike code or hang up to terminate the call A double beep after the unit answers indicates both that Tenant Initiated Entry is enabled and that the access code is disabled so the user can let the visitor in using the doorstrike code without having to enter the access code or terminat...

Page 12: ...stance Monday 8am 4pm and Tuesday through Friday 8am 5pm central time So that we can give you better service before you call please 1 Know the model number the serial number and what software version you have see serial label 2 Have your Product manual in front of you 3 It is best if you are on site RETURNING PRODUCT FOR REPAIR The following procedure is for equipment that needs repair 1 Customer ...

Reviews: