Installation

IMPORTANT:

  Electronic devices are susceptible to lightning and power station electrical surges from both the AC 

outlet and the telephone line.  It is recommended that a surge protector be installed to protect against such surges. 

A.  Mounting

VIKING

©

1

2

3

4

5

6

7

8

9

0

  

#

*

9

0

#

*

  

8

7

6

5

4

3

2

1

Optional VE-5x10 Surface Mount 

Box (not included), see DOD# 424

10.0"

9.5"

4.50"

2.596"

5.00"

8.65"

0.425"

0.952"

Front View

of the K-1270

9.12"

2.5"

4.5"

Zinc-Plated Steel

Rough-In Box

(included)

Side View

of the K-1270

(8) #6-32 x 1/2" Stainless 

Steel, 5/64" T-10 Torx 

Security Screws 

(included)

  

  

14 Gauge Marine 

Grade 316 Stainless 

Steel Faceplate

10.14"

3.69"

5.22"

- OR -

B.  Changing the Directory

Paper Directory

Directory
Lens

  

C.  Wiring

Color

Function

Black

Power In 

Black

Power In 

Green

Phone Line In

Red

Phone Line In

Brown

Door Strike Relay common

Orange

Door Strike Relay NC

Yellow

Door Strike Relay NO

Blue

Camera Relay common

Violet

Camera Relay NC

White

Camera Relay NO

The 

K-1270

 is designed to be installed in a sheltered location, and is not meant to be used outdoors. For outdoor 

applications use the 

K-1270-EWP

. The 

K-1270

 can either be installed as a flush mount unit using the included 

rough in box, or as a surface mount unit using an optional 

VE-5x10

. The rough in box uses the inner set of four 

holes on the face plate while the 

VE-5x10

 uses the outside set of holes. A set of dummy screws and nuts are 

provided to fill the unused mounting holes.

To install a directory, remove the four screws that mount 
the  directory  lens  to  the  front  of  the 

K-1270 

using  the 

included Allen wrench. Insert a paper directory behind the 
lens and secure the two back onto the front panel being 
careful to align the names with the front panel graphics. 
For your convenience, the back of this document has pre-
printed directory forms. 

Note: 

To print directory forms for the 

K-1270

, go to 

www.vikingelectronics.com and enter “930” in the DOD 
field at the top of the page for a direct link to the PDF.

The

 K-1270

 can be powered from any source supplying 12 

to 24 volts, AC or DC. A 12 volt DC adapter is supplied with 
the product. When using the included adapter, the plug on 
the  adapter  cord  will  have  to  be  removed.  The  power 
connections to the 

K-1270

 (black wires) are not polarity 

sensitive. 

There  are  also  8  more  wires  connected  to  the 

K-1270

 

controller board. Two wires are for the incoming phone line, 
three are from the high current door strike relay and the last 
three are from the camera relay. Gel filled butt connectors 
are provided for easier connection to building wiring. The 
table at the right describes each wire’s function. 

3

Summary of Contents for K-1270 Series

Page 1: ...Mylar speaker Self draining mic mount Faceplate keypad mic and speaker gaskets Designed to meet IP66 Ingress Protection Rating see DOD 859 Operates on 12 to 24 volts AC DC 12 speed dial buttons 22 digits each 12 alternate number positions 22 digits each One button operation no call button Hang up on CPC busy silence time out or dial tone Touch tone restriction from microphone Integral relays for c...

Page 2: ...c Die cast with Satin Chrome Finish internally sealed per IP67 Speaker Screen Speaker screen with 0 018 wide slots to prevent punctures from paperclips etc Faceplate Material 14 gauge 316 stainless steel with 4 brushed finish Speaker Mylar speaker with rubber gasket to maintain water tight seal and eliminate water deterioration Blue Call LED Lights steady to help locate the button in low light Mic...

Page 3: ...urface mount unit using an optional VE 5x10 The rough in box uses the inner set of four holes on the face plate while the VE 5x10 uses the outside set of holes A set of dummy screws and nuts are provided to fill the unused mounting holes To install a directory remove the four screws that mount the directory lens to the front of the K 1270 using the included Allen wrench Insert a paper directory be...

Page 4: ... more information VIKING VIKING ELECTRONICS HUDSON WI 54016 STAND ALONE DOOR CONTROLLER ENTRY SYSTEM POWER 12V DC MODEL ES 1 1 POWER PROGRAM PHONE LOG BUS 2 3 4 5 GANG PROG 6 7 8 9 WIEGAND DEVICE 10 11 DOOR STRIKE N O 2 1 L H COM N C BLK RED GRN WHT Doorstrike 12V DC Adapter included with ES 1 OR Share power with 12 24V AC DC door strike with 200mA available current or use the included 12V DC adap...

Page 5: ... door strike will energize for the programmed Door Strike Time Note To prevent unwanted radio interference route the connecting wires through the included ferrite core Note The gel filled water tight butt connectors are designed for insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Cut off stripped ends prior to terminating Rear View of the K 1270 CO Line Yellow...

Page 6: ...el C 1000B not included Doorstrike Magnetic Lock 120V AC 120V AC 120V AC D Using the K 1270 with a C 3000 For a No CO installation a Viking C 3000 No CO controller can be used with the K 1270 Note the K 1270 will need to be programmed on a separate CO line or use the Viking DLE 200B The door strike can be controlled by the K 1270 or the internal relay on the C 3000 just be sure to disable the door...

Page 7: ... DC maximum not included Doorstrike Power Supply Doorstrike 1 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 2 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 3 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 4 Entry Point 3 K 1275 K 1275 E Add Relay Control for up to 4 K 1270 75 Proximity Card Readers IMPORTANT Electronic devices are suscepti...

Page 8: ...ing programming If this happens check to see that DIP switch 1 is ON so the unit is set to answer incoming calls Then turn DIP switch 4 ON to allow accessing programming without the security code Call the line attached to the K 1270 With the phone ringing press the 0 button on the K 1270 keypad The K 1270 should answer the line and you should hear two beeps indicating that you are in the programmi...

Page 9: ...p to twelve 46 digit numbers Each number can also be programmed with special features such as pauses and the Touch Tones Q and Each of the special characters count as a single digit Each of the speed dial positions 01 to 12 pertain to the corresponding button on the front of the K 1270 The button 0 uses position 10 the Q uses position 11 and the uses position 12 To program a speed dial position en...

Page 10: ...eration for a functional description of this feature Tenant Initiated Entry is disabled by default To enable it enter programming see Programming section A Enter 38 Also DIP switch 1 must be turned ON and left in this position to enable the K 1270 to answer incoming calls To disable Tenant Initiated Entry enter 37 Security considerations with Tenant Initiated Entry The K 1270 door entry system is ...

Page 11: ...ess code following the single beep hear two acknowledgement beeps and then either let the visitor in using the doorstrike code or hang up to terminate the call A double beep after the unit answers indicates both that Tenant Initiated Entry is enabled and that the access code is disabled so the user can let the visitor in using the doorstrike code without having to enter the access code or terminat...

Page 12: ...stance Monday 8am 4pm and Tuesday through Friday 8am 5pm central time So that we can give you better service before you call please 1 Know the model number the serial number and what software version you have see serial label 2 Have your Product manual in front of you 3 It is best if you are on site RETURNING PRODUCT FOR REPAIR The following procedure is for equipment that needs repair 1 Customer ...

Reviews: