background image

6

C.  Using the K-1270 with a C-1000B

In some instances it may be a concern that the Door Strike relay is outside the door. In this situation, a second 
controller  such  as  a 

C-1000B

  can  be  used.  Be  sure  to  disable  the  door  strike  code  for  the 

K-1270

  (see 

Programming

 section 

H

).  

Notes:

1. The 

C-1000B

 must be in the “Analog Station Mode” (refer to the 

C-1000B

 Product Manual).  

2. The 

K-1270

 keyless entry codes can not be used in this application.  

3. The 

K-1270

 will hang up during doorstrike activation.

DOOR ENTRY / CCTV VIDEO

CONTROLLER

VIKING

©

MODEL C-1000B

PWR 13.8 V

A

C

DOOR

STRIKE 1

DOOR

STRIKE 2

DOORBOX 2

DOORBOX

PWR OUTPUT

DOORBOX 1

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19

EARTH

GND 

PHONE LINE

INPUT

LINE OUT

TO PHONES

KEYLESS CONTACT

CLOSURE INPUT

VIKING

ELECTRONICS

HUDSON, WI 54016

EARTH

GND

C.O. LINE

INPUT

OUT TO

PHONES

KEYLESS

C.C. INPUT

DOOR
BOX 1

DOORBOX

13VAC PWR

DOOR
BOX 2

N.O.   COM   N.C.
DOOR STRIKE 1

SIG    GND
VIDEO 1 IN

SIG    GND
VIDEO 2 IN

SIG    GND

VIDEO OUT

N.O.   COM   N.C.
DOOR STRIKE 2

TALK     BATTERY
OFF            ON

C

LED1

C
LED2

C
LED3

ON

 1     2     3

COM                N.O.   N.C. - - - - AUX.

CONTACT

OUTPUT

13.8V AC

Adapter

(included)

Talk Battery Switch

OFF

ON

CO line or Analog

PABX/KSU Station

Earth

 Ground

5A@30V DC/
250V AC maximum

Red

Green

ON

 1     2     3

DIP Switches 

Model K-1270

ON

OFF

Model C-1000B

(not included)

 Doorstrike / Magnetic Lock

120V AC

120V AC

120V AC

D.  Using the K-1270 with a C-3000

For a “No CO” installation, a Viking 

C-3000

 No CO controller can be used with the 

K-1270

. Note, the 

K-1270

 will 

need to be programmed on a separate CO line or use the Viking 

DLE-200B

. The door strike can be controlled by 

the 

K-1270

 or the internal relay on the 

C-3000

, just be sure to disable the door strike feature in the other unit. The 

keyless entry feature of the 

C-3000

 can not be used. If not using keyless entry codes, use the 

C-3000

 to control 

the doorstrike. If using keyless entry codes (up to 50), use the 

K-1270

 to control the doorstrike. The 

K-1270

 speed 

dial position should be programmed with the 

C-3000

 line selection command “1” to “12”. (Refer to the 

C-3000

 

Technical Practice for more details, DOD# 162).

Model K-1270

120V AC

VIKING

©

MODEL C-3000

 

VIKING

ELECTRONICS

HUDSON, WI 54016

12 UNIT APARTMENT

ENTRY CONTROLLER MODULE 

POWER

13.8 VAC

3 4 5 6 7

1 2

DOOR

STRIKE

1

DOOR

STRIKE

2

DIP

SWITCH

1  2  3

RJ21X

12 APARTMENT LINES IN/OUT

8

ENTRY

PHONE 1

MULTI-MODULE

INTERCONNECTS

POSTAL

LOCK
INPUT

ENTRY

PHONE 2

OUT              IN

PWR

IN

USE

PROGRAM PHONE

O

N

O

F

F

Red

Red

Green

Green

Model C-3000

(not included)

120V AC

120V AC

Model K-1270

Notes:

1. In this application, the 

C-3000

 keyless entry feature is not available. Use the keyless entry  

    feature of the 

K-1270

 and wire both door strike relays in parallel.   

2. The 

K-1270

 will hang up during the doorstrike activation.

Summary of Contents for K-1270 Series

Page 1: ...Mylar speaker Self draining mic mount Faceplate keypad mic and speaker gaskets Designed to meet IP66 Ingress Protection Rating see DOD 859 Operates on 12 to 24 volts AC DC 12 speed dial buttons 22 digits each 12 alternate number positions 22 digits each One button operation no call button Hang up on CPC busy silence time out or dial tone Touch tone restriction from microphone Integral relays for c...

Page 2: ...c Die cast with Satin Chrome Finish internally sealed per IP67 Speaker Screen Speaker screen with 0 018 wide slots to prevent punctures from paperclips etc Faceplate Material 14 gauge 316 stainless steel with 4 brushed finish Speaker Mylar speaker with rubber gasket to maintain water tight seal and eliminate water deterioration Blue Call LED Lights steady to help locate the button in low light Mic...

Page 3: ...urface mount unit using an optional VE 5x10 The rough in box uses the inner set of four holes on the face plate while the VE 5x10 uses the outside set of holes A set of dummy screws and nuts are provided to fill the unused mounting holes To install a directory remove the four screws that mount the directory lens to the front of the K 1270 using the included Allen wrench Insert a paper directory be...

Page 4: ... more information VIKING VIKING ELECTRONICS HUDSON WI 54016 STAND ALONE DOOR CONTROLLER ENTRY SYSTEM POWER 12V DC MODEL ES 1 1 POWER PROGRAM PHONE LOG BUS 2 3 4 5 GANG PROG 6 7 8 9 WIEGAND DEVICE 10 11 DOOR STRIKE N O 2 1 L H COM N C BLK RED GRN WHT Doorstrike 12V DC Adapter included with ES 1 OR Share power with 12 24V AC DC door strike with 200mA available current or use the included 12V DC adap...

Page 5: ... door strike will energize for the programmed Door Strike Time Note To prevent unwanted radio interference route the connecting wires through the included ferrite core Note The gel filled water tight butt connectors are designed for insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Cut off stripped ends prior to terminating Rear View of the K 1270 CO Line Yellow...

Page 6: ...el C 1000B not included Doorstrike Magnetic Lock 120V AC 120V AC 120V AC D Using the K 1270 with a C 3000 For a No CO installation a Viking C 3000 No CO controller can be used with the K 1270 Note the K 1270 will need to be programmed on a separate CO line or use the Viking DLE 200B The door strike can be controlled by the K 1270 or the internal relay on the C 3000 just be sure to disable the door...

Page 7: ... DC maximum not included Doorstrike Power Supply Doorstrike 1 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 2 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 3 5A 30V DC maximum not included Doorstrike Power Supply Doorstrike 4 Entry Point 3 K 1275 K 1275 E Add Relay Control for up to 4 K 1270 75 Proximity Card Readers IMPORTANT Electronic devices are suscepti...

Page 8: ...ing programming If this happens check to see that DIP switch 1 is ON so the unit is set to answer incoming calls Then turn DIP switch 4 ON to allow accessing programming without the security code Call the line attached to the K 1270 With the phone ringing press the 0 button on the K 1270 keypad The K 1270 should answer the line and you should hear two beeps indicating that you are in the programmi...

Page 9: ...p to twelve 46 digit numbers Each number can also be programmed with special features such as pauses and the Touch Tones Q and Each of the special characters count as a single digit Each of the speed dial positions 01 to 12 pertain to the corresponding button on the front of the K 1270 The button 0 uses position 10 the Q uses position 11 and the uses position 12 To program a speed dial position en...

Page 10: ...eration for a functional description of this feature Tenant Initiated Entry is disabled by default To enable it enter programming see Programming section A Enter 38 Also DIP switch 1 must be turned ON and left in this position to enable the K 1270 to answer incoming calls To disable Tenant Initiated Entry enter 37 Security considerations with Tenant Initiated Entry The K 1270 door entry system is ...

Page 11: ...ess code following the single beep hear two acknowledgement beeps and then either let the visitor in using the doorstrike code or hang up to terminate the call A double beep after the unit answers indicates both that Tenant Initiated Entry is enabled and that the access code is disabled so the user can let the visitor in using the doorstrike code without having to enter the access code or terminat...

Page 12: ...stance Monday 8am 4pm and Tuesday through Friday 8am 5pm central time So that we can give you better service before you call please 1 Know the model number the serial number and what software version you have see serial label 2 Have your Product manual in front of you 3 It is best if you are on site RETURNING PRODUCT FOR REPAIR The following procedure is for equipment that needs repair 1 Customer ...

Reviews: