46
Calling up code 1
Press the following keys:
1.
d
+
å
simultaneously for approx. 4 s.
The
"Service"
menu appears.
2.
|
/
~
for
"Code 1"
.
3.
d
to confirm.
4.
|
/
~
for the required group.
5.
d
to confirm.
6.
|
/
~
for the required coding address.
7.
d
to confirm.
8.
|
/
~
for the required value.
9.
d
to confirm.
"Adopted"
appears briefly on the dis-
play.
10.
ä
Exit the service menu.
Overview
The coding addresses are displayed in groups, subject
to system configuration:
■
"General"
■
"Hardware"
■
"Heating"
■
"Boiler"
■
"DHW"
■
"Additional heat source"
General
Coding
Coding in the delivered condition
Possible change
Detached house/apartment building
7F:1
Detached house, same holiday
program for all heating groups
7F:0
Apartment building, holiday program
can be adjusted separately
Minimum temperature buffer sensor top
91:0
No minimum temperature
91:0
to
91:95
If a combined heating water buffer
cylinder is installed, a minimum tem-
perature can be set for the top of the
buffer cylinder (captured by PTS 1).
Hardware
Coding
Coding in the delivered condition
Possible change
Additional boiler
Additional boil-
er:No
No additional boiler installed
Additional boil-
er:Yes
Additional boiler installed
Buffer
Buffer:3
No heating water buffer cylinder in-
stalled
Buffer:3
Heating water buffer cylinder with 3
buffer temperature sensors installed
Buffer:4
Heating water buffer cylinder with 4
buffer temperature sensors installed
Buffer:5
Heating water buffer cylinder with 5
buffer temperature sensors installed
Codes
Code 1
5777 985 GB
Codes