Fitting the side panels and back panel
Route external cables through the opening in the back
panel.
A
3,9 x 9,5
4.
3.
1.
5.
2.
Fig. 12
A
Type plate
Secure the side panels with the screws supplied.
Electrical connections
When connecting external switching contacts and
components to the safety low voltage of the control
unit, the relevant safety requirements of protection
class II must be observed. This means 8.0 mm air and
creep paths or 2.0 mm insulation thickness against live
components.
Ensure the safe electrical separation of all on-site com-
ponents (incl. PCs/laptops) in accordance with
EN 60 335 and IEC 65.
!
Please note
Electronic assemblies can be damaged by elec-
trostatic discharge.
Prior to commencing any work, touch earthed
objects such as heating or water pipes to dis-
charge static loads.