28
System version 4
One heating circuit without mixer A1 with a separate heating circuit pump and
one heating circuit with mixer M2 (with/without DHW heating)
M
6
5
7
8
9
qP
1
4
2
3
1
Vitoladens 300-W
2
Outside temperature sensor
3
DHW cylinder
4
Cylinder temperature sensor
5
Heating circuit without mixer A1
6
Heating circuit pump A1
7
Heating circuit with mixer M2
8
Temperature limiter for limiting the
maximum temperature of underfloor
heating systems
9
Flow temperature sensor M2
qP
Heating circuit pump M2
Extension kit for one heating circuit
with mixer M2
Required coding
Address
Max. speed of the internal circulation pump in heating mode:
20%
31:20
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5692 799 GB