Coding in the delivered condition
Possible change
65:...
Information regarding the
type of diverter valve (not
adjustable)
65:0
Without diverter valve
65:1
Diverter valve by
Viessmann
65:2
Diverter valve by Wilo
65:3
Diverter valve by Grundfos
67:40
In conjunction with the
Vitosolic solar control
unit: Third set DHW value
67:0
to
67:60
Set DHW value adjustable
from 0 to 60 °C
6C:100
Set speed; internal circu-
lation pump with DHW
heating 100 %
6C:0
to
6C:100
Set speed adjustable from
0 to 100 %
6F:100
Maximum output for
DHW heating 100 %,
defaulted by the boiler
coding card
71:0
DHW circulation pump
"ON" according to time
program
71:1
"OFF" during DHW heating
to the first set value
71:2
"ON" during DHW heating
to the first set value
72:0
DHW circulation pump
"ON" according to time
program
72:1
"OFF" during DHW heating
to the second set value
72:2
"ON" during DHW heating
to the second set value
73:0
DHW circulation pump
"ON" according to time
program
73:1
to
73:6
During the time program
1x/h "ON" for 5 min
up to 6x/h "ON" for 5 min
73:7
Permanently "ON"
General
76:0
Without LON communi-
cation module
76:1
With LON communication
module (automatic recog-
nition)
Codes
Code 2
(cont.)