Coding in the delivered condition
Possible change
Fb:30
Duration for raising the
set boiler water tem-
perature or the set flow
temperature (see cod-
ing address "FA")
60 min. See example on
page 101 (only for
weather-compensated
control units).
Fb:0
to
Fb:150
Duration adjustable from
0 to 300 min;
1 step
≙
2 min
Resetting codes to their delivered condition
Constant temperature control unit:
1.
L
+
G
simultaneously for
approx. 2 s.
2.
e
press.
Weather-compensated control unit:
1.
L
+
G
simultaneously for
approx. 2 s.
2.
e
"
Factory set? Yes
"
appears.
3.
d
to confirm
or
a
/
b
to select "
Factory set?
No
".
Code 2
(cont.)
60
Coding
5692
673
GB