Parameter ad-
dress b5:...
With heating circuit pump logic function: Heating cir-
cuit pump OFF, if
1:
enabled RT
actual
> RT
set
+ 5 K; disabled RT
actual
< RT
set
+ 4 K
2:
enabled RT
actual
> RT
set
+ 4 K; disabled RT
actual
< RT
set
+ 3 K
3:
enabled RT
actual
> RT
set
+ 3 K; disabled RT
actual
< RT
set
+ 2 K
4:
enabled RT
actual
> RT
set
+ 2 K; disabled RT
actual
< RT
set
+ 1 K
5:
enabled RT
actual
> RT
set
+ 1 K; disabled RT
actual
< RT
set
6:
enabled RT
actual
> RT
set
; disabled RT
actual
< RT
set
- 1 K
7:
enabled RT
actual
> RT
set
- 1 K; disabled RT
actual
< RT
set
- 2 K
8:
enabled RT
actual
> RT
set
- 2 K; disabled RT
actual
< RT
set
- 3 K
Coding in the delivered condition
Possible change
Boiler circuit, mixer circuit
C5:20
Electronic minimum
flow temperature limit
20 °C (only for weather-
compensated control
units)
C5:1
to
C5:127
Minimum temperature
limit adjustable from 1 to
127 °C (limited by boiler-
specific parameters)
C6:74
Electronic maximum
flow temperature limit
74 °C (only for weather-
compensated control
units)
C6:10
to
C6:127
Maximum temperature
limit adjustable from 10 to
127 °C (limited by boiler-
specific parameters)
d3:14
Heating curve slope =
1.4 (only for weather-
compensated control
units)
d3:2
to
d3:35
Heating curve slope ad-
justable from 0.2 to 3.5
(see page 29)
d4:0
Heating curve level = 0
(only for weather-com-
pensated control units)
d4:
–
13
to
d4:40
Heating curve level ad-
justable from
–
13 to 40
(see page 29)
d5:0
The external heating
program changeover al-
ters the heating pro-
gram to "Constant
operation with reduced
room temperature"
(only for weather-com-
pensated control units)
d5:1
The external operating
mode changeover alters
to "Constant central heat-
ing with standard room
temperature"
Code 2
(cont.)
56
Coding
5692
673
GB
Summary of Contents for VITODENS 300-W
Page 111: ...Parts lists cont 111 Parts lists 5692 673 GB...
Page 112: ...Parts lists cont 112 Parts lists 5692 673 GB...
Page 113: ...Parts lists cont 113 Parts lists 5692 673 GB...
Page 114: ...Parts lists cont 114 Parts lists 5692 673 GB...
Page 121: ...121 5692 673 GB...
Page 122: ...122 5692 673 GB...
Page 123: ...123 5692 673 GB...