Coding in the delivered condition
Possible change
E9:45
Speed of the external
variable speed heating
circuit pump 45 % of the
max. speed during op-
eration with reduced
room temperature (only
for weather-compen-
sated control units)
E9:0
to
E9:100
Speed adjustable from 0
to 100 % of the maximum
speed during operation
with reduced room tem-
perature
F1:0
Screed drying function
disabled (only for
weather-compensated
control units).
F1:1
to
F1:6
Screed drying function
adjustable in accordance
with 6 optional tempera-
ture/time profiles (see
page 98)
F1:15
Constant flow tempera-
ture 20 °C
F2:8
Time limit for party
mode 8 hours or exter-
nal heating program
changeover via the key-
board (only for weather-
compensated control
units)
*
1
F2:0
No time limit for party
mode
F2:1
to
F2:12
Time limit adjustable from
1 to 12 hours
*
1
F5:12
Run-on time of the inter-
nal circulation pump in
heating mode 12 min
(only for constant tem-
perature control units)
F5:0
No run-on time for the in-
ternal circulation pump
F5:1
to
F5:20
Run-on time of the inter-
nal circulation pump ad-
justable from 1 to 20 min
F6:25
In the "DHW only" oper-
ating mode, the internal
circulation pump is per-
manently ON (only for
constant temperature
control units)
F6:0
In the "DHW only" operat-
ing mode, the internal cir-
culation pump is
permanently OFF
F6:1
to
F6:24
In the "DHW only" operat-
ing mode, the internal cir-
culation pump will be
started for 10 min respec-
tively 1 to 24 times per
day.
Code 2
(cont.)
58
Coding
5692
673
GB
*1
Party mode ends
automatically
in heating program "
rw
" when the system changes
over to operation with standard room temperature.
Summary of Contents for VITODENS 300-W
Page 111: ...Parts lists cont 111 Parts lists 5692 673 GB...
Page 112: ...Parts lists cont 112 Parts lists 5692 673 GB...
Page 113: ...Parts lists cont 113 Parts lists 5692 673 GB...
Page 114: ...Parts lists cont 114 Parts lists 5692 673 GB...
Page 121: ...121 5692 673 GB...
Page 122: ...122 5692 673 GB...
Page 123: ...123 5692 673 GB...