System version 5
One heating circuit with mixer M1 (with Vitotronic 200-H), one heating cir-
cuit with mixer M2 (with extension kit) and low loss header (with/without
DHW heating)
1
Vitodens 300-W
2
Outside temperature sensor
3
DHW cylinder
4
Cylinder temperature sensor
5
Heating circuit with mixer M1
6
Flow temperature sensor M1
7
Heating circuit pump M1
8
Vitotronic 200-H
9
Heating circuit with mixer M2
qP
Temperature limiter for limiting the
max. temp. of underfloor heating
systems
Flow temperature sensor M2
qW
Heating circuit pump M2
qE
Extension kit for one heating cir-
cuit with mixer M2
qR
Low loss header
qT
Flow temperature sensor, low loss
header
Required coding
Address
Operation with LPG
82:1
One heating circuit with mixer with extension kit for mixer
and one heating circuit with mixer with Vitotronic 200-H
&
with DHW cylinder
00:4
&
without DHW cylinder
00:3
Further details regarding the individual steps
(cont.)
28
Commissioning, inspection, maintenance
5692
673
GB