75
Instantaneous heating water heater
Parameters for
Instantaneous heating water heater
Setting
"Electr booster heater"
Ó
"Enable instantaneous heating water heater
7900"
"1"
"Electr booster heater"
Ó
if applicable
"Enable instant. heating water heater for cen-
tral heating 7902"
"1"
"Electr booster heater"
Ó
"Output for instant. heating water heater at
power-OFF 790A"
■
"1"
for 3 kW
■
"2"
for 6 kW
■
"3"
for 9 kW
"DHW"
Ó
if applicable
"Enable electric heaters for DHW heating
6015"
"1"
External heat source
External heat source parameters
Setting
"External heat source"
Ó
"Enable external heat source 7B00"
"1"
With circulation pump for DHW reheating:
"External heat source"
Ó
"Enable booster heaters for DHW heating
6014"
"1"
"External heat source"
Ó
"Enable external heat source for DHW heating
7B0D"
"1"
Immersion heater
Immersion heater parameters
Setting
"DHW"
Ó
"Enable electric heaters for DHW heating
6015"
"1"
"DHW"
Ó
"Enable booster heaters for DHW heating
6014"
"1"
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5782 176 GB
Service