30
Plug
sYA
Terminals Function
Explanation
211.5
AC
Type AWB-AC:
Cooling control
3-way diverter valves for
heating water buffer cylin-
der bypass in cooling
mode
Connection values
■ Max. output: 10 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
Connect the 3-way diverter valves for the
bypass circuit in parallel.
Plug
sYS
Terminals
Function
Explanation
212.2
A1
Heating circuit pump for
heating circuit without mixer
(A1/HC1)
■ This pump is connected in addition to
the secondary pump if a heating water
buffer cylinder is installed.
■ Connect the temperature limiter to re-
strict the maximum temperature for un-
derfloor heating systems (if installed) in
series (see the following chapter)
Connection values
■ Output: 100 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
212.3
DHW circulation pump
Connection values
■ Output: 50 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
Installation sequence
Electrical connections
(cont.)
5782 176 GB