Viessmann
5443203
37
|
SCU224
Indication of collector temperatures
Indicates the current collector temperature.
•
COL : collector temperature (1-collector system)
•
COL1 : collector temperature 1
•
COL2 : collector temperature 2
COL, COL1, COL2:
Collector temperature
Display range: -40 ... +500 °F
[-40 ... +260 °C]
Indication of tank temperatures
Indicates the current tank temperature.
•
TST :
tank temperature (1-tank system)
•
TSTB :
tank temperature bottom
•
TSTT :
tank temperature top
(Arr = 3 and 4 only)
•
TST1 :
temperature tank 1 (2-tank-systems)
•
TST2 :
temperature tank 2 (2-tank-systems)
•
TDIS :
thermal disinfection temperature
(Arr = 3 only; replaces TSTT if, during thermal disin-
fection, the heating period DDIS is active)
TST, TSTB, TSTT,
TST1, TST2, TDIS:
Tank temperatures
Display range: -40 ... +500 °F
[-40 ... +260 °C]
Indication of sensors 3 and 4
Indicates the current temperature of the corresponding
additional sensor (without control function).
•
S3
: temperature sensor 3
•
S4
: temperature sensor 4
S3, S4:
Sensor temperatures
Display range: -40 ... +500 °F
[-40 ... +260 °C]
Indication of other temperatures
Indicates the current temperature of the corresponding
sensor.
•
TSFB : temperature solid fuel boiler
•
TRET : temperature heating return preheating
•
TR : temperature return
TSFB, TRET, TR:
Other mea sured tempe ratures
Display range: -40 ... +500 °F
[-40 ... +260 °C]
Note:
S3 and S4 will only be indicated if the temperature
sensors are connected.
Initialization
Indicates the time adjusted in
tDTO
, running backwards.
INIT:
ODB initialization active
Filling time
Indicates the time adjusted in
tFLL
, running backwards.
FLL:
ODB filling time active
Stabilization
Indicates the time adjusted in
tSTB
, running backwards.
STAB:
Stabilization
4.1 Display channels
Note:
The displayed values and adjustment channels
depend on which system layout, which options
and functions have been selected. Only values
and adjustment channels available for the indivi-
dual settings selected will appear in the menu.
Indication of drainback time periods
4. Channel overview