Danger
Damaged cable insulation can
cause injury and damage to the
appliance.
Route cables so that they cannot
touch very hot, vibrating or sharp-
edged components.
Danger
Incorrect wiring can lead to life-
threatening injuries from electri-
cal current and result in appliance
damage.
■ Route LV leads < 42 V and
> 42 V/230 V~/400 V~ cables
separately.
■ Strip the insulation from the
cables as close to the terminals
as possible, and bundle tightly
to the corresponding terminals.
■ Secure cables with cable ties/
strain relief fittings.
This ensures that, should there
be a fault, for example when
detaching a wire, the wires can-
not drift into the adjacent voltage
area.
When routing the on-site cables,
observe the location of the cable entries
into the appliance at its back panel.
Install additional strain relief clamps for
the power cables if the clearance behind
the heat pump is greater than 80 mm.
Installation sequence
Making the electrical connections