39
F3
sXG sXF
sXD sXS
sYA
sYS
Fig.33
Set the required parameters during commissioning;
see from page 57.
Working components 230 V~
Plug
sYA
Terminals
Function
Explanation
211.3
r
1.
Instantaneous heating water heater
switching, stage 1.
Connection values
■
Output: 10 W
■
Voltage: 230 V~
■
Max. switching current: 4(2) A
Connection, see separate "Connection and wiring dia-
gram" sheet 110.
211.5
NC
Cooling control
NC function (natural cooling) or NC
signal for AC function (active cooling)
Connection values
■
Output: 10 W
■
Voltage: 230 V~
■
Max. switching current: 4(2) A
Connection:
■
NC function, see separate "Connection and wiring
diagram" sheet 191, sheet 192
■
AC function, see separate "Connection and wiring
diagram" sheet 201, sheet 203
Installation sequence
Overview of electrical connections
(cont.)