78
Coding in the delivered condition
Possible change
Cylinder temperature sensor at so-
lar control module, type SM1, is
used for heat source temperature.
1B:2
Sensor 10 at solar control module,
type SM1, is used for heat source
temperature.
1C:0
Never adjust
1D:40
Never adjust
"DHW"
Select
"DHW"
(see page 71).
Coding
Coding in the delivered condition
Possible change
56:0
Set DHW temperature adjustable
from 10 to 60 °C
56:1
Set DHW temperature adjustable
from 10 to above 60 °C
Note
Maximum value dependent on cod-
ing card
Observe the maximum permissible
DHW temperature.
58:0
Without auxiliary function for DHW
heating
58:10
to
58:60
Input of a second set DHW tempera-
ture, adjustable from 10 to over
60 °C (observe coding address "56")
59:0
Cylinder heating:
Start point
–
2.5 K
Stop point +2.5 K
59:1
to
59:10
Start point adjustable from 1 to 10 K
below set value
5b:0
DHW cylinder connected directly to
the boiler
5b:1
DHW cylinder connected down-
stream of the low loss header
5E:0
Circulation pump for cylinder heat-
ing remains in control mode at "Ex-
ternal blocking" signal.
5E:1
Circulation pump for cylinder heating
stops at "External blocking" signal.
5E:2
Circulation pump for cylinder heating
starts at "External blocking" signal.
5F:0
Circulation pump for cylinder heat-
ing remains in control mode at "Ex-
ternal demand" signal.
5F:1
Circulation pump for cylinder heating
stops at "External demand" signal.
5F:2
Circulation pump for cylinder heating
starts at "External demand" signal.
60:20
During DHW heating, the secon-
dary circuit flow temperature is
max. 20 K higher than the set
DHW temperature.
60:5
to
60:25
The differential between flow tem-
perature and set DHW temperature
is adjustable from 5 to 25 K
62:2
Circulation pump with 2 min run-on
time after cylinder heating
62:0
No circulation pump run-on
62:1
to
62:15
Run-on time adjustable from 1 to
15 min
65:...
Information on the type of diverter
valve (never adjust; specified by
the coding card)
Code 2
"Process"
(cont.)
5678 044 GB
Codes