65
Select
"Boiler"
(see page 63).
Coding
Coding in the delivered condition
Possible change
Burner service in 100 hours
21:0
No service interval set (in hours
run)
21:1
to
21:100
The number of hours run before the
burner should be serviced is adjust-
able from 100 to 10,000 h
One step
≙
100 h
Service interval in months
23:0
No time set for burner service in-
terval
23:1
to
23:24
Time interval adjustable from 1 to
24 months
Service status
24:0
"Service"
not shown on the dis-
play
24:1
"Service"
shown on the display.
The coding address is set automati-
cally and must be reset manually af-
ter a service.
Filling/Venting
2F:0
Secondary circuit:
Venting program/filling program not
active
2F:1
Venting program active
2F:2
Filling program active
"Process"
Select
"Process"
(see page 63).
Coding
Coding in the delivered condition
Possible change
Enable sorption operation
14:0
Only condensing operation ena-
bled
14:1
Only sorption operation enabled
14:2
Condensing operation and sorption
operation enabled
Heat source
1A:1
Solar thermal
1A:0
Geothermal probe
Code 1
"Boiler"
5678 044 GB
Codes