Solar parameters
Setting
"Solar"
Ó
"Type solar control unit 7A00"
"4"
"Solar"
Ó
"Flow rate solar circuit for calculating solar
yield 7A07"
Specify the value calculated from
the set pump rate of the solar cir-
cuit pump and the pressure drop
in the solar circuit.
Cooling function
Cooling function parameters
Setting
"Cooling"
Ó
"Cooling function 7100"
■
"0"
(no cooling)
■
"2"
(natural cooling on cooling
circuit without mixer)
■
"3"
(natural cooling on cooling
circuit with mixer)
"Cooling"
Ó
"Cooling circuit 7101"
■
"1"
(heating circuit A1)
■
"2"
(heating circuit M2)
■
"4"
(separate cooling circuit)
Instantaneous heating water heater
Parameters for
instantaneous heating water heater
Setting
"Electr booster heater"
Ó
"Enable instantaneous heating water heater
7900"
"1"
"Electr booster heater"
, if applicable
Ó
"Enable instant. heating water heater for cen-
tral heating 7902"
"1"
"Electr booster heater"
Ó
"Output for instant. heating water heater at
power-OFF 790A"
■
"1"
for 3 kW
■
"2"
for 6 kW
■
"3"
for 9 kW
"DHW"
, if applicable
Ó
"Enable electric heaters for DHW heating
6015"
"1"
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5601 598 GB
Service
Summary of Contents for BWT 241.A Series
Page 20: ...20 aCH 11 10 193C SLP N 224 6 9 Installation sequence Siting the heat pump cont 5601 598 GB...
Page 22: ...22 4x 4x 6x 2x 22 19 21 20 Installation sequence Siting the heat pump cont 5601 598 GB...
Page 23: ...23 4x 23 2x 26 25 24 Installation sequence Siting the heat pump cont 5601 598 GB Installation...
Page 27: ...27 C D BB Installation sequence Siting the heat pump cont 5601 598 GB Installation...
Page 71: ...71 Opening programming unit 2 2x 1 3 Troubleshooting Repairs cont 5601 598 GB Service...
Page 123: ...123 5601 598 GB...