Parameters for circulation pumps and other components
Heating circuit pump
Parameter
Setting
"System definition"
Ó
"System scheme 7000"
■
With heating circuit A1/HC1 without
mixer
or
■
With heating circuit M2/HC2 with
mixer
or
■
With heating circuit M3/HC3 with
mixer
Circulation pump for cylinder heating
Parameter
Setting
"System definition"
Ó
"System scheme 7000"
With DHW heating
DHW circulation pump
Parameter
Setting
Extended menu
Ó
"Time program DHW circulation"
Set a time program.
Circulation pump for DHW reheating
Parameter
Setting
"External heat source"
Ó
"Enable external heat source 7B00"
"1"
"Enable external heat source for DHW heating 7B0D"
"1"
Mixer extension kit for heating circuit M3/HC3
Parameter
Setting
"System definition"
Ó
"System scheme 7000"
With heating circuit M3/HC3
Note
Set rotary switch S1 in the extension
kit to "2": See "Mixer extension kit" in-
stallation instructions.
Remote control for heating/cooling circuit or Vitocomfort 200
Parameter
Setting
"Heating circuit 1"
/
"Heating circuit 2"
/
"Heating circuit 3"
Ó
"Remote control 2003"
or
"Remote control 3003"
or
"Remote control 4003"
"1"
Note
To assign a heating circuit, set the
code at the remote control:
See "Vitotrol" installation instructions.
Commissioning, inspection, maintenance
Commissioning the system
(cont.)
5516461
Summary of Contents for BW 301.B06
Page 69: ...69 Fig 49 Maintenance Opening the casing door 5516461 Maintenance...
Page 76: ...76 Maintenance Condensation and moisture in the heat pump cont 5516461 Maintenance...
Page 79: ...79 Parts lists type BWC 301 B Parts not shown type BWC 301 B cont 5516461 Components...
Page 88: ...88 Parts lists type BWC 301 B Hydraulics type BWC 301 B cont 5516461 Components...
Page 91: ...91 Parts lists type BW 301 B Parts not shown type BW 301 B cont 5516461 Components...
Page 100: ...100 Parts lists type BW 301 B Hydraulics type BW 301 B cont 5516461 Components...
Page 103: ...103 Parts lists type BWS 301 B Parts not shown type BWS 301 B cont 5516461 Components...